Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 10,
  • Issue 1,
  • pp. 37-44
  • (2002)

Effect of Sample Presentation and Animal Muscle Species on the Analysis of Meat by near Infrared Reflectance Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

The useful wavelengths in both the visible and the near infrared region as well as two sample presentations (intact and minced) were evaluated to assess moisture (M), crude protein (CP) and intra muscular fat (IMF) in lamb (n = 300), beef (n = 100) and chicken (n = 48) muscle samples. Samples were scanned in reflectance in a NIRSystems 6500 (NIRSystems, Silver Spring, MD, USA). Predictive equations were performed using modified partial least squares (MPLS) with internal cross-validation. The coefficient of determination in calibration (R2CAL) and the standard error in cross-validation (SECV) were calculated for each chemical parameter. For moisture, crude protein and fat (each expressed as g kg−1), R2CAL and SECV for beef muscle were 0.98, 0.81 and 0.96, respectively, and SECV was 33.1, 21.8 and 44.8 for beef muscle; for chicken muscle the comparable statistics were 0.99, 0.97 and 0.95 and SECV was 6.9, 2.4 and 33.1; while for lamb muscle R2CAL was 0.76, 0.83 and 0.73 and SECV 10.3, 5.5 and 4.7. It was concluded that the minced presentation is the best way to analyse muscle samples. On the other hand, intact presentation could have a great potential for use in the meat industry, although more research will be needed in order to determine quality attributes on meat samples.

© 2002 NIR Publications

PDF Article
More Like This
Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy

Nassim Nasseri, Stefan Kleiser, Daniel Ostojic, Tanja Karen, and Martin Wolf
Biomed. Opt. Express 7(11) 4605-4619 (2016)

Accuracy and stability improvement for meat species identification using multiplicative scatter correction and laser-induced breakdown spectroscopy

Yan Wu Chu, Shi Song Tang, Shi Xiang Ma, Yu Yang Ma, Zhong Qi Hao, Yang Min Guo, Lian Bo Guo, Yong Feng Lu, and Xiao Yan Zeng
Opt. Express 26(8) 10119-10127 (2018)

Meat species identification accuracy improvement using sample set portioning based on joint x–y distance and laser-induced breakdown spectroscopy

Lianbo Guo, Weinan Zheng, Feng Chen, Weiliang Wang, Deng Zhang, Zhenlin Hu, and Yanwu Chu
Appl. Opt. 60(20) 5826-5831 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.