Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Position controlled lasing threshold of the acceptor emission in a dynamic twin droplet system made using a microfluidic chip

Not Accessible

Your library or personal account may give you access

Abstract

We demonstrate low threshold acceptor lasing consequent to the efficient coupling and radiative energy transfer between the donor and acceptor droplets in a dynamic array of coupled droplets named twin droplets, made using a microfluidic chip. The ability of the microdroplet to focus the incoming plane wave internally along the principle diameter, by virtue of its spherical interface and higher refractive index than the background medium, is recognized as the prime cause of observed acceptor lasing in the coupled droplet system. This is confirmed by observing only acceptor fluorescence when the refractive index of the donor droplet falls below that of the background. By flipping the position of the acceptor in the twin droplets, we further show that the threshold of the acceptor lasing is dependent on the acceptor position and, hence, the coupling direction. Using the emission polarization measurements from the twin droplets, we also show that the acceptor emission is highly polarized and follows the pump laser polarization.

© 2022 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Versatile optofluidic ring resonator lasers based on microdroplets

Wonsuk Lee, Yunhan Luo, Qiran Zhu, and Xudong Fan
Opt. Express 19(20) 19668-19674 (2011)

Spectral tuning of lasing emission from optofluidic droplet microlasers using optical stretching

Mehdi Aas, Alexandr Jonáš, Alper Kiraz, Oto Brzobohatý, Jan Ježek, Zdeněk Pilát, and Pavel Zemánek
Opt. Express 21(18) 21380-21394 (2013)

Supplementary Material (1)

NameDescription
Supplement 1       Supplemental document.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.