Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 9,
  • Issue 3,
  • pp. 199-210
  • (2001)

Prediction and Classification of Tenderness in Beef from Non-Invasive Diode Array Detected NIR Spectra

Not Accessible

Your library or personal account may give you access

Abstract

NIR absorbance spectra of 48 beef samples were recorded 2, 9 and 21 days post mortem in the wavelength range 950–1700 nm with a Zeiss MCS 511 instrument equipped with diode array detector. These spectra were used to predict tenderness of the meat samples when Warner–Bratzler (WB) shear force was used as the reference method. Two types of prediction models were made. The models were either based on NIR spectra alone or NIR spectra in combination with information about post slaughter treatments. Prediction models from NIR spectra alone gave correlation coefficients in the range 0.52–0.83, but when variables for post slaughter treatments were included in the models the correlation coefficients were in the range 0.71–0.85. The additional variables had no effect on the prediction results when tenderness was predicted at the same time as NIR spectra were acquired, but improvements were found when tenderness was forecast later than the spectral acquisition. Based on these prediction models the beef samples were classified into two or three tenderness groups. When the beef samples were classified into two groups, 73–98% of the samples were correctly classified, while there were 63–75% correct classified samples when they were allocated into three groups.

© 2001 NIR Publications

PDF Article
More Like This
Line-scan Raman scattering image and multivariate analysis for rapid and noninvasive detection of restructured beef

Xuecheng Li, Zhenfang Liu, Min Huang, and Qibing Zhu
Appl. Opt. 60(22) 6357-6365 (2021)

Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing

Wanjie Zhang, Rong Liu, Wen Zhang, Hao Jia, and Kexin Xu
Biomed. Opt. Express 4(6) 789-802 (2013)

Absorption spectra of early stool from preterm infants need to be considered in abdominal NIRS oximetry

Helene Isler, Daniel Schenk, Jérôme Bernhard, Stefan Kleiser, Felix Scholkmann, Daniel Ostojic, Alexander Kalyanov, Linda Ahnen, Martin Wolf, and Tanja Karen
Biomed. Opt. Express 10(6) 2784-2794 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.