Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 16,
  • Issue 4,
  • pp. 371-380
  • (2007)

Hyperspectral Imaging System Calibration Using Image Translations and Fourier Transform

Not Accessible

Your library or personal account may give you access

Abstract

In this paper, we describe a methodology based on imaging system shifting and Fourier transform to recover the spatial distribution of the sensivity of a hyperspectral imaging system. The methodology mainly adresses a hyperspectral imaging system based on a CCD sensor for proximity image acquisition. The principle is to look several times at the same scene by moving the camera slightly (a few millimetres) at each acquisition. Thus, it is possible to separate what moves (scene) from what remains fixed (response of the system) using properties of Fourier transform. Tests on synthetic images have reinforced theorical results on contraint shifts and given good results with more than ten translations. Tests on real and in-laboratory images have shown the need for accurate determination of translation to avoid some disruptive effects (pattern multiplication). Nevertheless, the results are promising and have shown the potential of the methodology to correct images from spatial non-uniformity due to the imaging system (radiometric aberration due to the sensor and optic). We notice that such a methodology remains valid for any imaging system based on a charged-coupled device (CCD) sensor.

© 2008 IM Publications LLP

PDF Article
More Like This
Geometric calibration of a hyperspectral imaging system

Žiga Špiclin, Jaka Katrašnik, Miran Bürmen, Franjo Pernuš, and Boštjan Likar
Appl. Opt. 49(15) 2813-2818 (2010)

Radiometric calibration and noise estimation of acousto-optic tunable filter hyperspectral imaging systems

Jaka Katrašnik, Franjo Pernuš, and Boštjan Likar
Appl. Opt. 52(15) 3526-3537 (2013)

Infrared hyperspectral upconversion imaging using spatial object translation

Louis Martinus Kehlet, Nicolai Sanders, Peter Tidemand-Lichtenberg, Jeppe Seidelin Dam, and Christian Pedersen
Opt. Express 23(26) 34023-34028 (2015)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.