A Comparison of Reflectance Pulse Oximetry and near Infrared Spectroscopy for the Determination of the Fraction of Oxygenated Haemoglobin at Low Oxygen Saturations in an Animal Study

Not Accessible

Your library or personal account may give you access

Abstract

Near infrared spectroscopy scans of cerebral tissue in vivo were compared to reflectance pulse oximetry of local tissue by comparing each method to in vitro femoral arterial blood measurements in an experimental study on 16 newborn piglets. To test the accuracy, the 16 piglets were desaturated stepwise during general anaesthesia, leading to the following results of linear regression analysis of complete data, linear regression analysis for individual piglets and bias ± precision (1SD). Local oxygen saturation (reflectance pulse oximetry) versus arterial (haemoximeter): linear regression analysis R2 = 0.92, n = 207, linear regression analysis for individual piglets: R2 = 0.95 ± 0.05*, p < 0.05 versus near infrared spectroscopy, bias ± precision (1SD): 0.15 ± 9.65%; cerebral tissue oxygenation index (near infrared spectroscopy) versus arterial (haemoximeter): linear regression analysis R2 = 0.26, n = 161, linear regression analysis for individuals R2 = 0.83 ± 0.15, bias ± precision (1SD) −3.33 ± 29%; cerebral concentration of delta oxygenated haemoglobin (near infrared spectroscopy, NIRO 300) versus the corresponding arterial parameter (haemoximeter): linear regression analysis R2 = 0.76, n = 189, linear regression analysis for individuals R2 = 0.90 ± 0.06, bias ± precision (1SD) −2.54 ± 3 μM cm−3. The results of reflectance pulse oximetry in local tissue correlated more closely to in vitro femoral arterial blood measurements (haemoximeter) than results of near infrared spectroscopy, in vivo.

© 2006 NIR Publications

PDF Article
More Like This
Evaluation of hyperspectral NIRS for quantitative measurements of tissue oxygen saturation by comparison to time-resolved NIRS

Matthew Kewin, Ajay Rajaram, Daniel Milej, Androu Abdalmalak, Laura Morrison, Mamadou Diop, and Keith St Lawrence
Biomed. Opt. Express 10(9) 4789-4802 (2019)

Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy

Nassim Nasseri, Stefan Kleiser, Daniel Ostojic, Tanja Karen, and Martin Wolf
Biomed. Opt. Express 7(11) 4605-4619 (2016)

Pulse oximetry optical sensor using oxygen-bound haemoglobin

Z. J. V Cohen, S. Haxha, and A. Aggoun
Opt. Express 24(9) 10115-10131 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.