Effects of Spectral Resolution on the Determination of Glucose in a Simulated Biological Matrix by Fourier Transform near Infrared Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

The effects of spectral resolution on the performance of partial least-squares (PLS) calibration models were studied in the context of an analysis for physiological levels of glucose by Fourier transform near infrared (NIR) spectrometry in the combination region of 5000 to 4000 cm−1. Employing a simulated biological matrix of varying levels of triacetin and bovine serum albumin in phosphate buffer, two spectral data sets were evaluated. Single-sided interferograms consisting of 16,384 points collected over a 15,801 cm−1 bandwidth were Fourier processed to yield spectra with a nominal 2 cm−1 point spacing. These interferograms were then progressively truncated before Fourier processing to form sets of spectra with reduced resolution. The lower-resolution spectra were also computed with varying levels of zero-filling to evaluate the effects of spectral dimensionality on the PLS models. Across the levels of resolution and zero-filling, 21 parallel groups of spectra were computed with each of the two data sets. Calibration studies were then performed with spectra in absorbance units. Predictive models for glucose were optimised in terms of spectral range, the number of PLS latent variables and the parameters of a pre-processing Fourier filter. Models were evaluated for their performance in both short-term and long-term predictions. Through this research, it was found that models based on spectra with a nominal resolution of 16 cm−1 performed as well as those computed with higher-resolution spectra. Over the range of 1–20 mM glucose, these models achieved values of the standard error of prediction (SEP) in the range of 0.5 mM for short-term predictions and 0.8 mM for predictions with spectra collected more than 200 days after the calibration data. These results are significant because they help to define the required instrumental characteristics of a potential dedicated NIR glucose sensor.

© 2006 NIR Publications

PDF Article
More Like This
Determination of glucose in whole blood samples by mid-infrared spectroscopy

Yoen-Joo Kim, Sangjoon Hahn, and Gilwon Yoon
Appl. Opt. 42(4) 745-749 (2003)

Design of a mechanical-tunable filter spectrometer for noninvasive glucose measurement

Vidi Saptari and Kamal Youcef-Toumi
Appl. Opt. 43(13) 2680-2688 (2004)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.