Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Simulation and measurement of systematic errors of stitching interferometry for high precision X-ray mirrors with large radius of curvature

Not Accessible

Your library or personal account may give you access

Abstract

To accurately measure the surface figure of curved mirrors with large radius of curvature (RoC) using stitching interferometry methods, three types of measurement errors are systematically studied, including retrace error, defocusing error within a single subaperture, and stitching angle error among different subapertures. It was found that part of the retrace error caused by the mismatch between the reference wavefront and reflected wavefront has little effect, while the overall retrace error, including the influence of the imperfect optical elements, will cause an error of 1–2 nm RMS within a single subaperture. Defocusing error will enlarge the error due to amplification of optical path error caused by the deviation of the position of the CCD. Because the error is mainly in the edge area, a slope threshold, which controls the maximum surface slope of each subaperture, can be optimized to reduce the effect of the defocus on stitching measurement error. Constant angle error among neighboring subapertures has the biggest accumulation effect on the final stitched figure. For the spherical mirror with RoC of 100 m of ${80}\;{\rm mm} \times {40}\;{\rm mm}$, the error of the one-dimensional residual profile is 4.67 nm PV, assuming a constant angle error of ${2} \times {{10}^{- 7}}\;{\rm rad}$. For the elliptical mirror with RoC of 60–140 m, it is more than 15 nm peak-to-valley (PV). It is because the profile difference caused by constant angle error is closer to a circle, which can be mostly removed after subtraction of a best-fit sphere. Based on the above error analysis, the developed algorithm-based stitching method was used to measure an elliptical cylindrical mirror of ${74}\;{\rm mm} \times {40}\;{\rm mm}$ with RoC of 60–140 m, and the result was compared with a slope measurement instrument from the Beijing Synchrotron Radiation Facility. After removing the best fitting ellipse profile, the one-dimensional difference between the two results is only 0.77 nm RMS, which demonstrated good measurement accuracy.

© 2021 Optical Society of America

Full Article  |  PDF Article
More Like This
Mixed stitching interferometry with correction from one-dimensional profile measurements for high-precision X-ray mirrors

Qiaoyu Wu, Qiushi Huang, Jun Yu, Yifan Zhu, Weichen Gu, Pengfeng Sheng, Yumei He, Hongxin Luo, Zhong Zhang, and Zhanshan Wang
Opt. Express 31(10) 16330-16347 (2023)

Accuracy analysis and improvement of an algorithm-based stitching interferometry method for curved mirrors with large radii of curvature

Xudong Xu, Qiushi Huang, Qiaoyu Wu, Yumei He, Xiaohao Dong, Jie Wang, Zhong Zhang, and Zhanshan Wang
OSA Continuum 2(10) 2783-2794 (2019)

Stitching interferometry for long X-ray mirrors with lateral multi-shift-based absolute calibration

Guang Zhou, Jiezhuo Wang, Weizheng Lei, Xiaohao Dong, and Jie Wang
Appl. Opt. 63(8) 2086-2094 (2024)

Data Availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (17)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (5)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.