Abstract
Measurement of two physical parameters with a single optical fibre length can be carried out using two independent measurements simultaneously. This paper reports on the analysis of the systematic errors associated with the measurement process. The effect of these errors is calculated for interferometric (Fabry-Perot), dual mode, polarimetric, dispersive fourier transform spectroscopy and fibre Bragg grating sensor systems.
© 1996 IEICE
PDF ArticleMore Like This
Harmeet Singh and Jim Sirkis
Tu51 Optical Fiber Sensors (OFS) 1996
Koustav Dey, Nikhil Vangety, and Sourabh Roy
ATh2K.5 CLEO: Applications and Technology (CLEO:A&T) 2022
D. G. Luke, R. McBride, R Lloyd, J. G. Burnett, A. H. Greenaway, and J. D. C. Jones
We37 Optical Fiber Sensors (OFS) 1996