Abstract
Three new methods of image recovery in computer tomography are used to reconstruct a simulated image from a set of limited-view data: affine transformations; circular interpolation from nonuniformly based samples; and convex projections. Because the latter uses prior information in a systematic fashion, the method of convex projection gave better results than the other methods.
© 1988 Optical Society of America