Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Optical Coherence Imaging Techniques and Imaging in Scattering Media V
  • Technical Digest Series (Optica Publishing Group, 2023),
  • paper 1263213
  • https://doi.org/10.1117/12.2672211

Speed detection to suppress motion artifacts (MA) in laser speckle contrast imaging (LSCI)

Not Accessible

Your library or personal account may give you access

Abstract

Laser speckle contrast imaging (LSCI) is an optical technique for noninvasive assessment of microcirculatory blood flow. LSCI has a broad application in medicine including dermatology. Since laser speckles are the basis for this imaging modality, any external motions during a measurement from both patient and operator affect the blood flow images. This challenge is called motion artefacts (MA). Here, we propose a complete procedure for analysis of speckles, that is, pre-segmentation, segmentation, motion detection, spatial alignment, perfusion map calculation and MA suppression. The handheld perfusion imager (HAPI) operated in both handheld and mounted schemes, has been used for measurements on 14 psoriasis subjects. The advantage of HAPI is use of a single monochromatic camera for both speckle imaging and motion detection. We make use of the black marker dots (made by the clinical investigator to determine visual psoriasis lesion boundary) for calculation of two-dimensional displacements of HAPI during each measurement (i.e. on-surface displacements). These on-surface displacements are integrated to translate each speckle image back to the initial position at the start of the measurement (i.e. spatial alignment). Furthermore, in handheld measurements, MA corrected blood flow maps (also called perfusion maps) are formed by extrapolation of a linear fit from local perfusion versus detected speed to the zero speed, that is, a value ideally always lower than the local mean perfusion. We show that our MA suppression technique makes handheld perfusion maps more similar to the associated mounted perfusion maps in term image histograms and mean values.

© 2023 SPIE

PDF Article
More Like This
Laser speckle correlation microscopy system to image microvascular perfusion

Soumyajit Sarkar, Mohammad Zaffar, and Hari M Varma
1262827 European Conference on Biomedical Optics (ECBO) 2023

Wavelet analysis of laser speckle contrast reveals new feature space for transcranial assessment of cerebral blood flow

Nadezhda Golubova, Elena Potapova, Evgeniya Seryogina, and Viktor Dremin
1262711 European Conference on Biomedical Optics (ECBO) 2023

Combined Multi-Wavelength Laser Speckle Contrast Imaging and Diffuse Reflectance Imaging for Skin Perfusion Assessment

A. Sdobnov, A. Bykov, A. Popov, I. Lihacova, A. Lihachev, J. Spigulis, and I. Meglinski
11075_49 European Conference on Biomedical Optics (ECBO) 2019

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.