Abstract

We have demonstrated a direct frequency comparison between two Sr87 lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique, based on the carrier-phase, was employed for a direct comparison, with a baseline of 9000 km between Japan and Germany. A frequency comparison was achieved for 83,640 s, resulting in a fractional difference of (1.1±1.6)×1015, where the statistical part is the largest contributor to the uncertainty. This measurement directly confirms the agreement of the two optical frequency standards on an intercontinental scale.

© 2014 Optical Society of America

Optical clocks have made rapid progress in the last ten years [1]. Following an aluminum ion clock [2], lattice clocks also reported accuracy as well as instability at the 1018 level [3]. Remote comparisons of optical clocks with this level of precision may work as a probe to detect differences in the gravitational redshift between different locations. Typical uncertainties in the level of the geoid surface currently amount to several centimeters, corresponding to differences in the redshift at the 1017 level. Furthermore, with the high frequency stability of optical clocks, temporal variations of the gravitational potential due to tidal effects become relevant at the 1017 level already at distances of a few 100 km. This dynamical shift may be estimated by monitoring the clock comparisons on an intercontinental scale, since differential tidal effects would become larger and observable in a short time. With global frequency comparisons, a variety of clock combinations may be established for testing fundamental postulates, like a search for violations of Einstein’s equivalence principle [4]. From a metrological aspect, on the other hand, frequency agreement confirmed by intercontinental comparisons proves the capability of optical clocks to generate and maintain standard frequencies worldwide, which will support the optical redefinition of the second.

Frequency comparisons of optical clocks have been realized mostly on-campus [2,3,59] except for two cases: a comparison of a Sr87 lattice clock at JILA against a neutral Ca clock at National Institute of Standards and Technology (NIST) with a 4-km-long optical fiber link [10], and between two Sr87 lattice clocks at National Institute of Information and Communications Technology (NICT) and the University of Tokyo (UT) using a 60-km long optical fiber [11]. Optical fiber links are promising at large distances, as demonstrated up to 1840 km [12]. To bridge intercontinental distances, however, satellite-based techniques are presently the only way. The global positioning system carrier-phase (GPSCP) technique, which has been the most precise satellite-based method, requires averaging times of more than a day to surpass an instability of 1×1015. As an alternative, carrier-phase-based two-way satellite time and frequency transfer (TWCP), first demonstrated by the U.S. Naval Observatory [13], is lately characterized in NICT for various ranges of baselines up to 9000 km, which is realized between NICT and the Physikalisch-Technische Bundesanstalt (PTB) in Germany [14,15]. Among satellite-based techniques, the TWCP technique has a superior short-term instability (evaluated to be at the 1013 level at 1 s) and is, thus, particularly suitable for comparing frequency standards with low instabilities, e.g., optical clocks.

In this Letter, two strontium lattice clocks, one at NICT in Japan [16] and the other at PTB [17,18] in Germany, are directly compared using the TWCP technique. The agreement of these two optical clocks, based on the same reference transition, was confirmed with an uncertainty of 1.6×1015. The baseline of 9000 km is the longest in direct comparisons of optical clocks.

Figure 1 shows the setup of the comparison. It consists of a TWCP setup, Sr87 lattice clocks, and frequency combs at each site. Both lattice clocks use the transition S10(F=9/2)P03(F=9/2) as reference. The accuracy of the Sr87 lattice clock at NICT and PTB is 2×1016 and 4×1017, respectively. Frequencies of the lattice clocks at each site are measured in reference to a local hydrogen maser (H-maser). At NICT, a Ti-sapphire-based frequency comb is stabilized to the H-maser and the clock frequency νNICT is obtained from the beat signal against the frequency comb. At PTB, the transfer oscillator method [19] is used to measure frequency ratios with fs-combs. The H-maser and the Sr clock are located in different buildings, each with an erbium-fiber-based frequency comb. These frequency combs are connected by stabilized optical fiber links. The frequency of the lattice clock at PTB νPTB is derived from relevant beat signals with a reference to the local H-maser. Additionally, a Yb+171 clock, based on the electric octupole transition S1/22(F=0)F27/2(F=3), is operated at PTB with a fractional uncertainty of less than 7×1017 [20,21]. Both the lattice clock and Yb+ clock are stable enough to assume that the frequency ratio of two clock frequencies is constant with an uncertainty at the 1017 level [18]. Thus, the Yb+ clock can extend the observation time when the PTB lattice clock is off-line. Note that zero dead-time counters are used in all parts of the experiment.

 figure: Fig. 1.

Fig. 1. Schematic of the frequency comparison of two Sr87 lattice clocks at NICT and PTB. Two-way satellite-based comparison using the carrier-phase measures the frequency difference of two local H-masers, through which the differential frequency of two clocks is derived. pps, pulse per second; TWCP, two-way carrier-phase (time and frequency transfer).

Download Full Size | PDF

In terms of the TWCP setup, we use a frequency band on a transponder of the geostationary satellite AM2, which is located at longitude 80° east. The transponder is available from 10:05 to 22:59 UTC per day. The elevation angles at NICT and PTB are 16.0° and 3.7°, respectively. In the two-way method, both ground stations transmit and receive microwave signals simultaneously. The carrier frequencies of the uplink and the downlink are, respectively, about 14 and 11 GHz. The uplink signals are referenced to the local H-masers while the downlink signals are measured against these H-masers. The carriers are modulated by narrowband pseudo-random noise to avoid fading and other perturbations. The group delay and the carrier-phase of the received signals were detected by demodulation using a replica code, by which we derived the fractional frequency difference of the two H-masers. The technical details of the TWCP system are described in [14,15]. The frequency ratio of the Sr87 lattice clocks is obtained through the ratio of the two H-masers in real time.

Figure 2 shows a typical time record of the fractional difference Δ(t)=νNICT(t)/νPTB(t)1. Each data point is the average of 60 s signal integration. The fractional difference includes corrections due to the systematic shifts of the clocks, as well as the gravitational redshift of 2.4(1.0)×1016 [16,22,23]. The frequency difference between uplink and downlink causes different delays due to the dispersion of the ionosphere. A compensation for this effect is applied, as discussed in [15]. We checked the data of Fig. 2 as well as the whole dataset for its sample autocorrelation ρ(τlag)=Δ(t+τlag)Δ(t)¯/σΔ2 at lag τlag, where σΔ2 is the variance of Δ(t) [24]. It is larger than 0.2 for the range of 0<τlag<150s and stays above 0.1 up to 700 s. This suggests that the clock comparison is neither characterized by white phase noise nor by white frequency noise.

 figure: Fig. 2.

Fig. 2. Record of the fractional frequency difference of one typical experimental day. Corrections of systematic shifts of the atomic clocks, as well as the compensation of ionospheric delays, are included. Each point is the result of 60 s signal integration.

Download Full Size | PDF

The Allan deviation of Δ(t) for the longest continuous recording (30,900 s, shown as the latter part of Fig. 2) is presented as the filled circles in Fig. 3. The reduction of the Allan deviation with the signal integration time is slower than in the case of white frequency noise, which confirms the autocorrelation analysis described above. We fitted the instability and obtained 7.5×1014τ0.37. Possible sources of instabilities are ambient temperature changes affecting the outdoor microwave equipment or imperfections of the ionosphere corrections.

 figure: Fig. 3.

Fig. 3. Allan deviation of the fractional frequency difference versus the averaging time. The instabilities shown as filled circles are derived from the latter part of Fig. 2, which contains 30,900 s of continuous data. The red solid and red dashed lines show the weighted fit and its extrapolation. Open circles are obtained by treating the whole 83,640 s as one continuous measurement, in which a part of the 13,840 s relies on the Yb+ clock. Instability is gradually reduced with a slope of τ0.37.

Download Full Size | PDF

We operated the clocks for several hours per day over four days and obtained simultaneous operation of the two lattice clocks for 69,840 s in total. This data set was extended by 13,800 s using the Yb+ clock at PTB, resulting in a total measurement of 83,640 s. The conversion coefficient of the Yb+ flywheel oscillator was derived from the measurement of 45,960 s, in which two optical clocks at PTB were both operated during the measurement campaign. The Allan deviation of this extended data set is shown in Fig. 3 as open circles. It agrees with the long-term instability obtained from extrapolation of the longest continuous data set, presented as filled circles.

The observed instability results from link instabilities, as the optical clocks have demonstrated much smaller instabilities. An upper limit for the link instabilities is obtained from the comparison of the TWCP link against the GPSCP link, which is totally independent from the TWCP. The comparison was done by measuring UTC(NICT) versus UTC(PTB) via the two link techniques during the four days of the measurement discussed here, as well as in a preceding study over two months. The Allan deviations of the link comparisons are shown in Fig. 4, which provide an upper limit of instability for each of the two satellite link techniques. As the measurement time of the optical clock comparison was limited, its instability did not fall below 1015 (Fig. 3); however, it is below the combined instability of the GPSCP and the TWCP links (Fig. 4). We estimate the statistical uncertainty of the frequency comparison by an extrapolation to the total measurement time using the observed instability progression and find 1.2×1015 for 83,640 s measurement time. This is consistent with the comparison of the two link techniques. The averaged frequency difference between the two link techniques was less than 1.0×1015 [15], which we assign as the systematic uncertainty of the link for the clock comparison. The impact of intermittent availability of the link is already included when we use this averaged frequency difference as the systematic uncertainty.

 figure: Fig. 4.

Fig. 4. Combined instability of satellite links: Allan deviation of the difference between the frequency comparisons of UTC(NICT) and UTC(PTB) obtained via TWCP and GPSCP. Filled squares in black show the performance during the four days as the direct frequency comparison of two Sr87 clocks while filled circles in red represent the measurement of March and April in 2013.

Download Full Size | PDF

By combining the systematic uncertainties of the lattice clocks (2×1016 and 4×1017) and the link (1.0×1015), as well as the statistical uncertainty (1.2×1015), we obtain the fractional uncertainty of the clock comparison as 1.6×1015. Using the averaged fractional frequency difference Δ=1.1×1015 along with a recent absolute frequency measurement of the PTB strontium lattice clock with an uncertainty of 3.9×1016 [18], the absolute frequency of the NICT strontium lattice clock is derived to 429 228 004 229 873.60 (71) Hz.

Figure 5 relates our clock comparison to other methods of remote frequency standard evaluations: an example for a precise comparison via local realizations of the second with Cs fountain clocks is given by the comparison of the Sr lattice clocks of PTB and Systèmes de Référence Temps-Espace (SYRTE) [8,18] (6×1016 uncertainty). In the absence of a local primary clock in operation, TAI-corrected H-masers are used as references and the obtained frequency can be compared with published frequency values, e.g., a recent measurement of NICT [16] versus the weighted mean of ten published strontium frequencies, resulting in a moderate agreement of 1.8(3.3)×1015. Moreover, one introduces a latency of a month to obtain the correction of the local UTC realization. Currently, the most accurate method for frequency comparisons are stabilized optical fiber links, through which optical clocks can be compared without significant loss of accuracy or stability [12]. The third data point of Fig. 5, taken from the NICT versus UT comparison [11], represents such a measurement with an uncertainty of 7×1016, which is mostly due to the compared clocks. The result presented in this Letter (bottom point in Fig. 5) has slightly larger uncertainty, but it is provided in real time and was obtained requiring neither a primary standard nor a fiber link.

 figure: Fig. 5.

Fig. 5. Overview of frequency comparisons of remote strontium lattice clocks using different methods.

Download Full Size | PDF

In summary, a direct frequency comparison between intercontinentally distant optical clocks was, for the first time to our knowledge, demonstrated using the TWCP method. Two strontium lattice clocks are located at NICT (Japan) and PTB (Germany), with the baseline distance of 9000 km. The clock frequencies agree with 1.1(1.6)×1015, which is dominated by the uncertainty contribution of the link. Further improvements may be achieved with more continuous measurement time and more careful control of ambient temperature of the link system. We expect to reach the 1016 level of accuracy in the near future, using commercially available ground stations modified to apply the TWCP technique. Optically generated microwaves [25,26] may replace H-masers as local references to synthesize the carrier frequency. Baselines capable of connecting continents and transportable ground stations may further fuel the interest in the demonstrated technique.

We thank N. Shiga, K. Kido, H. Ito, Y. Hanado, A. Bauch, J. Becker, and E. Peik for useful discussions and technical support. This research was supported in part by the FIRST Program of the Japan Society for the Promotion of Science, the Centre of Quantum Engineering and Space-Time Research (QUEST), and the projects International Timescales with Optical Clocks (ITOC) and High-accuracy optical clocks with trapped ions, which are both part of the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

References and Note

1. N. Poli, C. W. Oates, P. Gill, and G. M. Tino, Riv. Nuovo Cimento 12, 555 (2013).

2. C. W. Chou, D. B. Hume, J. C. J. Koelemeij, D. J. Wineland, and T. Rosenband, Phys. Rev. Lett. 104, 070802 (2010). [CrossRef]  

3. B. J. Bloom, T. L. Nicholson, J. R. Williams, S. L. Campbell, M. Bishof, X. Zhang, W. Zhang, S. L. Bromley, and J. Ye, Nature 506, 71 (2014). [CrossRef]  

4. C. M. Will, Living Rev. Relativity 9, 3 (2006). [CrossRef]  

5. N. Hinkley, J. A. Sherman, N. B. Phillips, M. Schioppo, N. D. Lemke, K. Beloy, M. Pizzocaro, C. W. Oates, and A. D. Ludlow, Science 341, 1215 (2013). [CrossRef]  

6. M. Takamoto, T. Takano, and H. Katori, Nat. Photonics 5, 288 (2011). [CrossRef]  

7. K. Matsubara, H. Hachisu, Y. Li, S. Nagano, C. Locke, A. Nogami, M. Kajita, K. Hayasaka, T. Ido, and M. Hosokawa, Opt. Express 20, 22034 (2012). [CrossRef]  

8. R. Le Targat, L. Lorini, Y. Le Coq, M. Zawada, J. Guena, M. Abgrall, M. Gurov, P. Rosenbusch, D. G. Rovera, B. Nagorny, R. Gartman, P. G. Westergaard, M. E. Tobar, M. Lours, G. Santarelli, A. Clairon, S. Bize, P. Laurent, P. Lemonde, and J. Lodewyck, Nat. Commun. 4, 2109 (2013).

9. D. Akamatsu, M. Yasuda, H. Inaba, K. Hosaka, T. Tanabe, A. Onae, and F. Hong, Opt. Express 22, 7898 (2014). [CrossRef]  

10. A. D. Ludlow, T. Zelevinsky, G. K. Campbell, S. Blatt, M. M. Boyd, M. H. G. de Miranda, M. J. Martin, J. W. Thomsen, S. M. Foreman, J. Ye, T. M. Fortier, J. E. Stalnaker, S. A. Diddams, Y. Le Coq, Z. W. Barber, N. Poli, N. D. Lemke, K. M. Beck, and C. W. Oates, Science 319, 1805 (2008). [CrossRef]  

11. A. Yamaguchi, M. Fujieda, M. Kumagai, H. Hachisu, S. Nagano, Y. Li, T. Ido, T. Takano, M. Takamoto, and H. Katori, Appl. Phys. Express 4, 082203 (2011). [CrossRef]  

12. S. Droste, F. Ozimek, Th. Udem, K. Predehl, T. W. Hänsch, H. Schnatz, G. Grosche, and R. Holzwarth, Phys. Rev. Lett. 111, 110801 (2013). [CrossRef]  

13. B. Fonville, D. Matsakis, A. Pawlitzki, and W. Schaefer, in Proceedings of 36th Annual PTTI Meeting (U.S. Naval Observatory, 2004), p. 149.

14. M. Fujieda, T. Gotoh, F. Nakagawa, R. Tabuchi, M. Aida, and J. Amagai, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 2625 (2012). [CrossRef]  

15. M. Fujieda, D. Piester, T. Gotoh, J. Becker, M. Aida, and A. Bauch, Metrologia 51, 253 (2014). [CrossRef]  

16. A. Yamaguchi, N. Shiga, S. Nagano, Y. Li, H. Ishijima, H. Hachisu, M. Kumagai, and T. Ido, Appl. Phys. Express 5, 022701 (2012). [CrossRef]  

17. St. Falke, H. Schnatz, J. S. R. Vellore Winfred, Th. Middelmann, St. Vogt, S. Weyers, B. Lipphardt, G. Grosche, F. Riehle, U. Sterr, and Ch. Lisdat, Metrologia 48, 399 (2011). [CrossRef]  

18. St. Falke, N. Lemke, C. Grebing, B. Lipphardt, S. Weyers, V. Gerginov, N. Huntemann, Ch. Hagemann, A. Al-Masoudi, S. Häfner, St. Vogt, U. Sterr, and Ch. Lisdat, “A strontium lattice clock with 3 × 10-17 inaccuracy and its frequency,” arXiv:1312.3419 (2013).

19. H. R. Telle, B. Lipphardt, and J. Stenger, Appl. Phys. B 74, 1 (2002). [CrossRef]  

20. N. Huntemann, M. Okhapkin, B. Lipphardt, S. Weyers, C. Tamm, and E. Peik, Phys. Rev. Lett. 108, 090801 (2012). [CrossRef]  

21. N. Huntemann, B. Lipphardt, M. Okhapkin, C. Tamm, E. Peik, A. V. Taichenachev, and V. I. Yudin, Phys. Rev. Lett. 109, 213002 (2012). [CrossRef]  

22. V. Gerginov, N. Nemitz, S. Weyers, R. Schröder, D. Griebsch, and R. Wynands, Metrologia 47, 65 (2010). [CrossRef]  

23. Temporal tidal effect is conservatively considered.

24. N. F. Zhang, Metrologia 43, S276 (2006). [CrossRef]  

25. A. Haboucha, W. Zhang, T. Li, M. Lours, A. N. Luiten, Y. Le Coq, and G. Santarelli, Opt. Lett. 36, 3654 (2011). [CrossRef]  

26. T. M. Fortier, M. S. Kirchner, F. Quinlan, J. Taylor, J. C. Bergquist, T. Rosenband, N. Lemke, A. Ludlow, Y. Jiang, C. W. Oates, and S. A. Diddams, Nat. Photonics 5, 425 (2011). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (5)

Fig. 1.
Fig. 1. Schematic of the frequency comparison of two Sr87 lattice clocks at NICT and PTB. Two-way satellite-based comparison using the carrier-phase measures the frequency difference of two local H-masers, through which the differential frequency of two clocks is derived. pps, pulse per second; TWCP, two-way carrier-phase (time and frequency transfer).
Fig. 2.
Fig. 2. Record of the fractional frequency difference of one typical experimental day. Corrections of systematic shifts of the atomic clocks, as well as the compensation of ionospheric delays, are included. Each point is the result of 60 s signal integration.
Fig. 3.
Fig. 3. Allan deviation of the fractional frequency difference versus the averaging time. The instabilities shown as filled circles are derived from the latter part of Fig. 2, which contains 30,900 s of continuous data. The red solid and red dashed lines show the weighted fit and its extrapolation. Open circles are obtained by treating the whole 83,640 s as one continuous measurement, in which a part of the 13,840 s relies on the Yb+ clock. Instability is gradually reduced with a slope of τ0.37.
Fig. 4.
Fig. 4. Combined instability of satellite links: Allan deviation of the difference between the frequency comparisons of UTC(NICT) and UTC(PTB) obtained via TWCP and GPSCP. Filled squares in black show the performance during the four days as the direct frequency comparison of two Sr87 clocks while filled circles in red represent the measurement of March and April in 2013.
Fig. 5.
Fig. 5. Overview of frequency comparisons of remote strontium lattice clocks using different methods.