Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Lightwave Technology
  • Vol. 29,
  • Issue 5,
  • pp. 782-788
  • (2011)

Intra-Cavity Spectroscopy Using Amplified Spontaneous Emission in Fiber Lasers

Not Accessible

Your library or personal account may give you access

Abstract

Fiber laser sources offer interesting possibilities for gas sensors since they can operate over an extended wavelength range, encompassing the near-IR absorption lines of a number of important gases but a major problem is that overtone absorption lines of gases in the near-IR are relatively weak. In order to enhance sensitivity, we present here a simple method of intra-cavity absorption spectroscopy (ICAS) which makes use of the amplified spontaneous emission (ASE) already present within a fiber laser cavity. The ASE also provides a convenient broadband source for the simultaneous interrogation of several gases within the gain-bandwidth of the fiber laser. The key principle is based on adjusting the cavity attenuation to select an appropriate inversion level where the fiber gain curve is flat. Under this condition, the ASE undergoes multiple circulations within the fiber laser cavity, enhancing the effective path-length of a gas cell placed within the laser cavity. A theoretical model of system operation is given and we have experimentally demonstrated the principle of operation with acetylene and carbon dioxide using a simple erbium fiber laser system containing a 6 cm path-length, fiber coupled, intra-cavity, micro-optic gas cell. We have experimentally simultaneously observed 16 absorption lines for 1% acetylene gas in the 1530 nm region and detected the very weak carbon dioxide lines in this same wavelength region. A path length enhancement of ${\sim}500$ in the linear regime has been demonstrated transforming the 6 cm micro-optic cell into an effective path length of ${\sim}30$ m. We also demonstrate how the enhancement factor may be calibrated by use of a simple fiber-optic interferometer. Apart from the OSA, all components are inexpensive and the system is very simple to construct and operate.

© 2011 IEEE

PDF Article
More Like This
Cavity-sensitive amplified spontaneous emission with radiation reabsorption

Ching-Hsu Chen, Chi-Lin Liu, and Sheng-Ti Chung
Opt. Lett. 38(24) 5315-5318 (2013)

Intra-cavity absorption spectroscopy with narrow-ridge microfluidic quantum cascade lasers

Mikhail A. Belkin, Marko Lončar, Benjamin G. Lee, Christian Pflügl, Ross Audet, Laurent Diehl, Federico Capasso, David Bour, Scott Corzine, and Gloria Höfler
Opt. Express 15(18) 11262-11271 (2007)

Influence of amplified spontaneous emission on laser linewidth in a fiber amplifier

Mingyuan Xue, Cunxiao Gao, Linquan Niu, Shaolan Zhu, and Chuandong Sun
Appl. Opt. 59(8) 2610-2614 (2020)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.