Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 72,
  • Issue 2,
  • pp. 177-187
  • (2018)

Calibration Procedure for Attenuation Coefficient Measurements in Highly Opaque Media Using Infrared Focal Plane Array (IRFPA) Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

The purpose of this article is to present a new calibration procedure for spectroscopic measurements using an infrared focal plane array (IRFPA) spectrometer on highly opaque middle-wave infrared (MWIR) media. The procedure is based on the properties of the IRFPA camera and especially the integration time (IT), which is the main parameter that can be adjusted to control the sensitivity of the measurements. The goal of the paper is to experimentally validate this dependence with the direct reference intensity light coming out of the IR monochromator in order to predict the spectrum shape and intensity level in a range out of the camera saturation. This method allows determining spectrum used as background for transmittance calculation. It has been applied in the case of measurement of water transmittance, which is a highly opaque medium and whose measurement requires high ITs. The main result is the ability to take an IR spectroscopic imaging measurement through 300 µm of water and the determination of its transmittance with sufficient sensitivity due to the proposed calibration procedure. This procedure allows the possibility of transitory studies in heterogeneous aqueous media.

© 2018 The Author(s)

PDF Article
More Like This
Solution for the nonuniformity correction of infrared focal plane arrays

Huixin Zhou, Shangqian Liu, Rui Lai, Dabao Wang, and Yubao Cheng
Appl. Opt. 44(15) 2928-2932 (2005)

Method for accurate measurement of infrared emissivity for opaque low-reflectance materials

Irina Vishnevetsky, Eyal Rotenberg, Abraham Kribus, and Dan Yakir
Appl. Opt. 58(17) 4599-4609 (2019)

Confocal corrected attenuation coefficient imaging in phantoms and in vivo using chromatic focal shift calibration

Johannes Kübler, Vincent S. Zoutenbier, Gijs Buist, Jörg Fischer, Arjen Amelink, and Johannes F. de Boer
Biomed. Opt. Express 14(10) 5282-5297 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator