Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 58,
  • Issue 6,
  • pp. 705-710
  • (2004)

Fast-Gated Intensified Charge-Coupled Device Camera to Record Time-Resolved Fluorescence Spectra of Tryptophan

Not Accessible

Your library or personal account may give you access

Abstract

The possibilities of a 200 ps gated intensified charge-coupled device (CCD) camera to record time-resolved fluorescence were explored using the fluorescing amino acid tryptophan and its derivative Nacetyl-tryptophan amide (NATA) as model compounds. The results were compared to complementary data from time-correlated single-photon counting (TCSPC) experiments. If a spectral resolution of 1–2 nm is desired, the fast-gated intensified CCD (ICCD) camera is the method of choice. For a 10<sup>-5</sup> M tryptophan solution, time-resolved emission spectra and intensity decays (measured over 12 ns at 25 ps resolution) could be obtained in typically 10 minutes, giving the well-known lifetimes of 0.5 and 3 ns. In addition, a longer lifetime of 7 ns was found at the red edge of the spectrum. The very short gate time of the ICCD camera allowed us to observe a shift in the emission maximum of tryptophan even within the first nanosecond of decay of the fluorescence emission. As expected from the tryptophan rotamer model, such a shift is not observed in NATA. Using amplitudes obtained by global analysis, decay-associated spectra of these lifetimes were constructed.

PDF Article
More Like This
256 × 2 SPAD line sensor for time resolved fluorescence spectroscopy

Nikola Krstajić, James Levitt, Simon Poland, Simon Ameer-Beg, and Robert Henderson
Opt. Express 23(5) 5653-5669 (2015)

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Jason T. Smith, Alena Rudkouskaya, Shan Gao, Juhi M. Gupta, Arin Ulku, Claudio Bruschini, Edoardo Charbon, Shimon Weiss, Margarida Barroso, Xavier Intes, and Xavier Michalet
Optica 9(5) 532-544 (2022)

Time-resolved DNA-microarray reading by an intensified CCD for ultimate sensitivity

G. Valentini, C. D’Andrea, D. Comelli, A. Pifferi, P. Taroni, A. Torricelli, R. Cubeddu, C. Battaglia, C. Consolandi, G. Salani, L. Rossi-Bernardi, and G. De Bellis
Opt. Lett. 25(22) 1648-1650 (2000)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.