Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 58,
  • Issue 12,
  • pp. 1488-1499
  • (2004)

Accuracy and Precision of Manual Baseline Determination

Not Accessible

Your library or personal account may give you access

Abstract

Vibrational spectra often require baseline removal before further data analysis can be performed. Manual (i.e., user) baseline determination and removal is a common technique used to perform this operation. Currently, little data exists that details the accuracy and precision that can be expected with manual baseline removal techniques. This study addresses this current lack of data. One hundred spectra of varying signal-to-noise ratio (SNR), signal-to-baseline ratio (SBR), baseline slope, and spectral congestion were constructed and baselines were subtracted by 16 volunteers who were categorized as being either experienced or inexperienced in baseline determination. In total, 285 baseline determinations were performed. The general level of accuracy and precision that can be expected for manually determined baselines from spectra of varying SNR, SBR, baseline slope, and spectral congestion is established. Furthermore, the effects of user experience on the accuracy and precision of baseline determination is estimated. The interactions between the above factors in affecting the accuracy and precision of baseline determination is highlighted. Where possible, the functional relationships between accuracy, precision, and the given spectral characteristic are detailed. The results provide users of manual baseline determination useful guidelines in establishing limits of accuracy and precision when performing manual baseline determination, as well as highlighting conditions that confound the accuracy and precision of manual baseline determination.

PDF Article
More Like This
Baseline correction for Raman spectra using a spectral estimation-based asymmetrically reweighted penalized least squares method

Yixin Guo, Weiqi Jin, Weilin Wang, Yuqing He, and Su Qiu
Appl. Opt. 62(18) 4766-4776 (2023)

Real-time control of micro/nanofiber waist diameter with ultrahigh accuracy and precision

Yingxin Xu, Wei Fang, and Limin Tong
Opt. Express 25(9) 10434-10440 (2017)

Real time and high-precision online determination of main components in iron ore using spectral refinement algorithm based LIBS

An Li, Xinyu Zhang, Xiaodong Liu, Yage He, Yuheng Shan, Haohan Sun, Wen Yi, and Ruibin Liu
Opt. Express 31(23) 38728-38743 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.