Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 56,
  • Issue 4,
  • pp. 515-520
  • (2002)

Comparison of Calibration Methods for the Monitoring of a Fluorobenzene Batch Reaction Using Low-Field 19F NMR, 1H NMR, NIR, and Raman Spectrometries

Not Accessible

Your library or personal account may give you access

Abstract

The suitability of different process spectrometry techniques has been assessed, in terms of calibration requirements, accuracy, and precision, for the at-line monitoring of the sulfonation of fluorobenzene. Partial least-squares (PLS) calibration was required to analyze the spectra obtained by NIR spectrometry and low-field (29.1 MHz) <sup>1</sup>H NMR spectrometry. The low-field (27.4 MHz) <sup>19</sup>F NMR spectra contained well-resolved signals for the three fluorine containing compounds and univariate calibration was adequate. The Raman spectra of two of the compounds exhibited fluorescence and so this technique was not considered suitable for monitoring the reaction. The accuracy of the results obtained using univariate analysis of the <sup>19</sup>F NMR data and PLS analysis of NIR data were comparable (average % error of 3.5 and 2.9%, respectively, for concentrations >0.5 mol dm<sup>-3</sup> and 11.3 and 11.1%, respectively, for <0.5 mol dm<sup>-3</sup>). The least accurate results were obtained using PLS analysis of low-field <sup>1</sup>H NMR data, as the spectra of two of the components were too similar. For concentrations >0.05 mol dm<sup>-3</sup>, the most precise results were obtained with PLS analysis of NIR data (average RSD of 1.6%), although the precision of the results obtained using univariate analysis of <sup>19</sup>F NMR data was still good (average RSD of 3.7%).

PDF Article
More Like This
Simultaneous analysis of Cr and Pb in contaminated pork by laser-induced breakdown spectroscopy

Mingyin Yao, Gangfu Rao, Lin Huang, Muhua Liu, Hui Yang, Jinyin Chen, and Tianbing Chen
Appl. Opt. 56(29) 8148-8153 (2017)

Detection of low levels of trichloroethylene vapor with Raman spectrometry

K. J. Ewing, T. Bilodeau, G. Nau, I. Schneider, and I. D. Aggarwal
Appl. Opt. 33(27) 6323-6327 (1994)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.