Applications of ICP-OES with a New Argon-Filled CCD Spectrometer Using Spectral Lines in the Vacuum Ultraviolet Spectral Range

Not Accessible

Your library or personal account may give you access

Abstract

It is shown that the use of analytical lines in the spectral range between 125 and 195 nm opens new analytical possibilities for inductively coupled plasma optical emission spectrometry (ICP-OES). Prominent emission lines in the vacuum ultraviolet (VUV) spectral region were used for different analytical applications with a new ICP optical emission spectrometer with charge-coupled device detectors (CCDs). These applications include the determination of Cl and S in organic samples (oil and gasoline), the determination of Al, Br, I, and P in high-saline 200 g/L NaCl solutions, and the determination of Pb, Sn, and In in highly pure 99.9% (m/m) Pd and Pt. The superiority of the VUV emission lines of Al 167, Br 148, Cl 134, Cl 135, Ga 141, I 161, In 158, P 177, Pb 168, Sn 140, and Sn 147 nm in these applications with respect to power of detection and freedom from spectral interferences is shown. The limits of detection (LODs) are tabulated for a series of further elements with prominent spectral lines in the 125-195 nm range using pneumatic nebulization of aqueous solutions for sample introduction. These results are compared with those for lines above 195 nm. In some cases VUV lines are superior to commonly used lines; for example, calculated LODs for Al(II) 167.080 nm, In(II) 158.637 nm, and Ga(II) 141.444 nm are 0.07, 0.2, and 0.8 μg/L, respectively, compared to 1.1, 7.1, and 5.9 μg/L for Al(I) 396.152, In(I) 230.606, and Ga I 417.204 nm, respectively. In other cases LODs in the μg/L range are possible only with VUV lines, such as for Cl(I) 134.724 or Br(I) 154.065 nm.

PDF Article
More Like This
Determination of absolute emission cross sections for electron-impact-induced line radiation in the vacuum ultraviolet

Wolfgang Jans, Bernd Möbus, Michael Kühne, Gerhard Ulm, Andreas Werner, and Karl-Heinz Schartner
Appl. Opt. 34(19) 3671-3680 (1995)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.