Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 52,
  • Issue 10,
  • pp. 1339-1347
  • (1998)

Matrix-Enhanced Calibration Procedure for Multivariate Calibration Models with Near-Infrared Spectra

Not Accessible

Your library or personal account may give you access

Abstract

A novel method is introduced for developing calibration models for the spectroscopic measurement of chemical concentrations in an aqueous environment. To demonstrate this matrix-enhanced calibration procedure, we developed calibration models to quantitate glucose and glutamine concentrations in an insect cell culture medium that is a complex mixture of more than 20 components, with three components that manifest significant concentration changes. Accurate calibration models were generated for glucose and glutamine by using a calibration data set composed of 60 samples containing the analytes dissolved in an aqueous buffer along with as few as two samples of the analytes dissolved in culture medium. Standard errors of prediction were 1.0 mM for glucose and 0.35 mM for glutamine. The matrix-enhanced method was also applied to culture medium samples collected during the course of a second bioreactor run. Addition of three culture medium samples to a buffer calibration reduced glucose prediction errors from 3.8 mM to 1.0 mM; addition of two culture medium samples reduced glutamine prediction errors from 1.6 mM to 0.76 mM. Results from this study suggest that spectroscopic calibration models can be developed from a relatively simple set of samples provided that some account for variations in the sample matrix.

PDF Article
More Like This
Multicomponent blood analysis by near-infrared Raman spectroscopy

Andrew J. Berger, Tae-Woong Koo, Irving Itzkan, Gary Horowitz, and Michael S. Feld
Appl. Opt. 38(13) 2916-2926 (1999)

Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing

Wanjie Zhang, Rong Liu, Wen Zhang, Hao Jia, and Kexin Xu
Biomed. Opt. Express 4(6) 789-802 (2013)

In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light

Sabbir Liakat, Kevin A. Bors, Tzu-Yung Huang, Anna P. M. Michel, Eric Zanghi, and Claire F. Gmachl
Biomed. Opt. Express 4(7) 1083-1090 (2013)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.