Absolute Detector Calibration Applied to Nonlinearity Error Correction in FT-IR Measurements

Not Accessible

Your library or personal account may give you access

Abstract

A method for correcting the effects of detector nonlinearity in Fourier transform infrared (FT-IR) spectrometers has been developed. The method incorporates directly measured results. No adjustable parameters are used. The absolute responsivity of two HgCdTe (MCT) detector/preamplifier systems as a function of incident photon flux was calibrated against a transfer-standard Ge detector with a diode laser source at 1.32 mu m. With the use of the MCT detector, preliminary measurements were made on an FT-IR spectrometer in both the near- and mid-infrared spectral regions. The measured nonlinear interferograms were corrected by using the detector response curve and the measured dc output of the preamplifier. In the resultant spectra, the nonzero values in the spectral region below the detector cutoff frequency were significantly reduced when the corrected interferograms were used. The transmittance spectra of a Si wafer and a neutral-density filter were measured with an MCT detector and a deuterated triglycine sulfate (DTGS) detector. Errors in transmittance caused by detector nonlinearity were greatly reduced with the use of the correction method.

PDF Article
More Like This
Reply to comments on "Absolute linearity measurements on a PbS detector in the infrared"

Evangelos Theocharous
Appl. Opt. 46(25) 6495-6497 (2007)

Absolute linearity measurements on HgCdTe detectors in the infrared region

Evangelos Theocharous, Juntaro Ishii, and Nigel P. Fox
Appl. Opt. 43(21) 4182-4188 (2004)

Detector nonlinearity correction scheme for the LPMA balloonborne Fourier transform spectrometer

Pascal Jeseck, Claude Camy-Peyret, Sébastien Payan, and Toufic Hawat
Appl. Opt. 37(27) 6544-6549 (1998)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.