Highly Sensitive Biochemical Analysis Using Low-Temperature Infrared Spectroscopy Measurements

Not Accessible

Your library or personal account may give you access

Abstract

A sensitive infrared spectroscopic analysis of biochemical components in an aqueous solution is described. The infrared spectrum of an aqueous solution containing glucose, urea, and creatinine was measured at - 4.7 C by Fourier transform infrared spectroscopy (FT-IR) with an attenuated total reflection (ATR) crystal. The infrared absorption bands of these components increased by about 100 times at - 4.7 C as compared with those measured at 22 C. This increase in the infrared absorption bands was found to occur because of segregation of the components toward the surface of the ATR crystal caused by solidification of the sample solution. The creatinine concentration in an aqueous solution, prepared in the physiological range of human blood, was also estimated at - 4.7 and 22 C by using the partial least-squares (PLS) method. The correlation coefficient between the predicted concentrations by PLS and the prepared concentrations was 0.95 at - 4.7 C, but was 0.07 at 22 C. Thus, the precision of the determination of creatinine was remarkably improved by using the low-temperature measurement.

PDF Article
More Like This
In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor

Songlin Yu, Dachao Li, Hao Chong, Changyue Sun, Haixia Yu, and Kexin Xu
Biomed. Opt. Express 5(1) 275-286 (2014)

Carbon dioxide laser based multiple ATR technique for measuring glucose in aqueous solutions

Yitzhak Mendelson, Been-chyuan Lin, Robert A. Peura, and Allen C. Clermont
Appl. Opt. 27(24) 5077-5081 (1988)

Temperature measurements of turbid aqueous solutions using near-infrared spectroscopy

Naoto Kakuta, Hidenobu Arimoto, Hideyuki Momoki, Fuguo Li, and Yukio Yamada
Appl. Opt. 47(13) 2227-2233 (2008)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.