Abstract
Off-plane x-ray reflection gratings are theoretically capable of achieving high resolution and high diffraction efficiencies over the soft x-ray bandpass, making them an ideal technology to implement on upcoming x-ray spectroscopy missions. To achieve high effective area, these gratings must be aligned into grating modules. X-ray testing was performed on an aligned grating module to assess the current optical alignment methods. Results indicate that the grating module achieved the desired alignment for an upcoming x-ray spectroscopy suborbital rocket payload with modest effective area and resolving power. These tests have also outlined a pathway towards achieving the stricter alignment tolerances of future x-ray spectrometer payloads, which require improvements in alignment metrology, grating fabrication, and testing techniques.
© 2018 Optical Society of America
Full Article | PDF ArticleCorrections
17 January 2018: A typographical correction was made to paragraph 1 in section 1.
More Like This
Ralf K. Heilmann, Jeffery Kolodziejczak, Alexander R. Bruccoleri, Jessica A. Gaskin, and Mark L. Schattenburg
Appl. Opt. 58(5) 1223-1238 (2019)
J. F. Seely, L. I. Goray, Benjawan Kjornrattanawanich, J. M. Laming, G. E. Holland, K. A. Flanagan, R. K. Heilmann, C.-H. Chang, M. L. Schattenburg, and A. P. Rasmussen
Appl. Opt. 45(8) 1680-1687 (2006)
W. Werner
Appl. Opt. 16(8) 2078-2080 (1977)