Abstract
An ultrasound-assisted micro-injection molding method is proposed to improve the rheological behavior of the polymer melt radically, and a micro-injection molding system based on a longitudinal ultrasonic vibration core is developed and employed in the micro-injection molding process of Fresnel lenses. The verification experiments show that the filling mold area of the polymer melt is increased by 6.08% to 19.12%, and the symmetric deviation of the Fresnel lens is improved 15.62% on average. This method improved the filling performance and replication quality of the polymer melt in the injection molding process effectively.
© 2015 Optical Society of America
Full Article | PDF ArticleMore Like This
Lei Chen, Stefan Kirchberg, Bing-Yan Jiang, Lei Xie, Yun-Long Jia, and Lei-Lei Sun
Appl. Opt. 53(31) 7369-7380 (2014)
Xiao-Hong Yin, Can Yang, Xi-Ping Li, Dong Liang, Zhong-Hua Zhang, Ying Tang, and Li-Jun He
Opt. Express 26(9) 11250-11264 (2018)
Chung Yen Wang and Pei Jen Wang
Appl. Opt. 53(11) 2523-2531 (2014)