Abstract
Hyperspectral absorption spectroscopy is being used to monitor gas temperature, velocity, pressure, and mole fraction in a research-grade pulsed-detonation combustor (PDC) at the Air Force Research Laboratory. The hyperspectral source employed is termed the TDM 3-FDML because it consists of three time-division-multiplexed (TDM) Fourier-domain mode-locked (FDML) lasers. This optical-fiber-based source monitors sufficient spectral information in the absorption spectrum near 1350 nm to permit measurements over the wide range of conditions encountered throughout the PDC cycle. Doppler velocimetry based on absorption features is accomplished using a counterpropagating beam approach that is designed to minimize common-mode flow noise. The PDC in this study is operated in two configurations: one in which the combustion tube exhausts directly to the ambient environment and another in which it feeds an automotive-style turbocharger to assess the performance of a detonation-driven turbine. Because the enthalpy flow [kilojoule/second] is important in assessing the performance of the PDC in various configurations, it is calculated from the measured gas properties.
© 2013 Optical Society of America
Full Article | PDF ArticleMore Like This
Andrew W. Caswell, Thilo Kraetschmer, Keith Rein, Scott T. Sanders, Sukesh Roy, Dale T. Shouse, and James R. Gord
Appl. Opt. 49(26) 4963-4972 (2010)
Keith D. Rein, Sukesh Roy, Scott T. Sanders, Andrew W. Caswell, Frederick R. Schauer, and James R. Gord
Appl. Opt. 55(23) 6256-6262 (2016)
R. M. Spearrin, C. S. Goldenstein, J. B. Jeffries, and R. K. Hanson
Appl. Opt. 53(9) 1938-1946 (2014)