Signal-to-noise criterion for free-propagation imaging techniques at free-electron lasers and synchrotrons

Open Access Open Access

Abstract

We propose a signal-to-noise criterion which predicts whether a feature of a given size and scattering strength, placed inside a larger object, can be retrieved with two common X-ray imaging techniques: coherent diffraction imaging and projection microscopy. This criterion, based on how efficiently these techniques detect the scattered photons and validated through simulations, shows in general that projection microscopy can resolve smaller phase differences and features than coherent diffraction imaging. Our criterion can be used to design optimized imaging experiments and perform feasibility studies for sensitive biological materials in free-electron lasers, where the number of photons per pulse is limited, or in synchrotron experiments, for both techniques.

© 2016 Optical Society of America

1. Introduction

The non-destructive imaging of soft biological material, such as bacteria, cells or tissue at a resolution of few tens of nanometers or less, is a widespread wish within the biology community [1, 2]. Modern X-ray techniques have been proved to be serious candidates for this task [3]. The debate on the ultimate achievable spatial resolution in coherent diffraction imaging, has been addressed in [4]. For continuous irradiation of the sample, as typically happens in a synchrotron, the resolution limit is dictated by radiation damage, and was claimed to be 10 nm for biological material [4]. As an alternative, the ultrashort and ultraintense X-ray pulses delivered by free-electron lasers (FELs) may serve to outrun the radiation damage [5], thus shifting the origin of the resolution limit from the maximal dose that can be deposited on the sample to the number of photons in an FEL X-ray pulse. These two approaches are the subject of the present work, which aims to shed light on the questions: (a) whether the resolution achievable on a single feature is hampered by the feature being embedded in a larger area illuminated with X-rays, and (b) if different imaging techniques exhibit different efficiency. For this comparison, we considered coherent diffraction imaging (CDI) [6] and propagation-based projection microscopy (PM) in holographic regime [7], as representative of reciprocal and real space methods, respectively.

PM imaging techniques require a small X-ray source [7], which may be a secondary focus [8], and were recently employed at synchrotron sources [9] achieving sub-100nm spatial resolution [10]. As illustrated in Fig. 1(a), the sample is placed at a small distance z1 downstream the source. The detector is positioned at a distance z2 further downstream to record a magnified Fresnel diffraction pattern, which forms according to Gabor’s holographic principle [11]. With a single diffraction pattern, the phase retrieval schemes are applicable only in special cases, for example for pure-phase objects [12, 13], and the retrieved phase generally is not reproduced quantitatively. A quantitative phase reconstruction, with a single diffraction pattern, can be achieved in some special cases, such as, single-material objects [14]. In general, this becomes possible if a number of patterns (typically 3 to 5) are acquired at different source-to-sample distances z1 [15–18], which ensures non-zero values of the contrast transfer function [15]. Another option is to use iterative approaches which impose constraints in the sample and detector planes [18]. The spatial resolution of the reconstructed phase map is in principle limited by the source size.

 figure: Fig. 1

Fig. 1 (a) PM setup, z1 is the source to sample distance (~ 10 µm), and z2 is the sample to detector distance (~ 1 m). (b) CDI setup, z is the distance from sample to detector.

Download Full Size | PDF

As an alternative imaging technique, we use CDI with plane wave illumination, typically achieved by focusing the beam at the sample position with a transversal size larger than the sample extension. A Fraunhofer diffraction pattern is detected in the far field, as shown in Fig. 1(b). The resolution is in principle given by the largest angle at which the intensity signal can be measured. Quantitative reconstruction of sample transmission amplitudes and phases from the measured intensity can be achieved by means of iterative transform algorithms (ITA) [6, 19], which rely on imposing additional constraints to the sample, for example a compact support.

The paper is organized as follows: in the next section we develop our signal-to-noise (SNR) criterion, based on Gaussian scatterers, which allows us to predict whether a feature of a given size and scattering contrast, placed inside a larger object can be retrieved for PM and CDI. In Section 3, we validate our model simulating both imaging techniques and evaluating the quality of the reconstructions. In Section 4, we apply our criterion to synchrotron and FEL experiments for the imaging conditions described in Section 3.

2. Signal-to-noise criterion

In this section, we develop a mathematical model, based on Gaussian scatterers, to predict the SNR for both techniques. Using the projection approximation [20] a 2D Gaussian scatterer is described by its transmission

t(x,y)=ej(ϕ¯+Δϕ(x,y)),
where ϕ¯ is the average phase of the object and Δϕ is the relative phase shift due to the Gaussian scatterer. In principle, ϕ¯ and Δϕ are complex valued. In this model the relative phase is given by
Δϕ(x,y)=ϕmaxe(x2+y2)2σ2,
where σ is the Gaussian width or standard deviation and is related to the size of our feature, ϕmax = 2π/λ (nn0)t0 is the maximum phase shift acquired by the wave front after crossing the scatterer, λ is the wavelength, n is the refractive index of the Gaussian scatterer, n0 is the refractive index of the background (e.g. water), and t0 is the maximum thickness of the scatterer. Within this article, we restrict the attention to weak pure phase objects. Biological material at photon energies between 2 and 20 keV is a prominent example, being the real part of the refraction index n small but orders of magnitude larger than its imaginary part. The parameter Δδnn0, at the energies we are studying, fulfills Δδ ≪ 1, leading to a weak-phase approximation ϕmax ≪ 1, which allows us to expand the exponential for the Δϕ term in Eq. (1).

In the following, we are going to discuss the circumstances under which nanoscale features can be imaged with PM and CDI methods. As a first step, we quantify the X-ray intensities diffracted by a single Gaussian feature (Eq. (2)) and measured with a pixel detector, using the weak-phase approximation. We calculate the SNR for both imaging techniques assuming Poissonian noise.

The parameters for the PM setup are shown in Fig 1(a). The beam with fluence Φ, emerging from a source of size fw, illuminates the sample uniformly over a field of view FOVPM. The defocusing distance is z = (z1z2)/(z1 + z2) [21] and the magnification is M = (z1 + z2)/z1. We use demagnified coordinates (x,y) = (xd,yd)/M to specify positions on the detector plane, corresponding to the physical coordinates (xd,yd). The X-ray intensity can be expressed by the sum of the non-scattered illumination (I0) plus the intensity containing the scatterer interaction (Isig)

I(x,y;z)=I0+Isig(x,y;z).

In the limit of Poisson noise statics and using the weak-phase approximation, the SNR for PM is given by (see for details [appendixA]Appendix A).

SNRPM(x,y;z)=Isig(x,y;z)I(x,y;z)Isig(x,y;z)I02NSω|A|ex2+y22σ2Re(A)|sin(ϕAx2+y22σIm(A))|,
where
A=11+j12πNF=|A|ejϕA,

NF = σ 2/λ z is the Fresnel number, ω = (ps/σ)2/π is related to the ratio between the sampling size (ps) and the Gaussian feature width, and NS is the total number of scattered photons

NS=ΦσS=Φ+|1t(x,y)|2dxdy=Φπσ2|ϕmax|2,
where σS is the total scattering cross section, as described in [4].

For CDI as depicted in Fig. 1(b), we illuminate with a fluence Φ a sample over a field of view FOVCDI. We will assume for the rest of the paper that our object covers an area smaller than half of the illuminated area by the FOVCDI. In case that our object is bigger than the illuminating beam, we would require a mask to fulfill the compact support condition [19]. In this scenario, the FOVCDI can be reinterpreted as 2×L, where L is the biggest dimension of the mask. Positions on the detector plane, located at a distance z downstream, are given in terms of reciprocal space coordinates (qx,qy) = 2π/(λz)(xd,yd). The SNR for CDI away from the direct beam (qx ≠ 0, qy ≠ 0) is given by (see for details [appendixA]Appendix A)

SNRCDI(qx,qy)=I(qx,qy)=NS2πσFOVCDIeσ2(qx2+qy2)2
where I(qx,qy) is the total intensity on the detector.

From Eqs. (4) and (7) it is clear that for both techniques the SNRs are proportional to NS. As a consequence, to compare both methods, it is crucial to understand how efficiently both techniques handle the scattered photons. We proceed by defining, for both imaging approaches, an effective SNR level which we will use later as imaging requirement to predict if a Gaussian feature embedded in a larger object can be recovered inside the retrieved overall image. In the NS ≪ 1 approximation, we require to detect the oscillation amplitude in Eq. (4). Thus we define

SNReffPM2NSω|A|2NS4πβ2σFOVPM,
where β = ps/fw and we have assumed a diffraction limited source (λz = πFOVPMfw/4).

For CDI, we require to have a significant SNR over the area given by qmax=qx2+qy2=π/σ with the sampling given by the FOVCDIq = 2π/FOVCDI)

SNReffCDINS2πσFOVCDI2ππqmax20qmaxeσ2q22qdqNS2σFOVCDI.

In the case that our feature is not isolated and it is embedded in a larger object, which scatters isotropically and more than our feature, we can reduce our effective signal-to-noise criterion by a factor 2, as our feature signal is dominated by the interference term [22]. We have already included this factor 2 in Eq. (9) and for the rest of the paper we will use this factor as this is generally the case for small features inside biological samples. In case the interference is negligible, such as for example when the feature is isolated and there are not other significant scatterers, one should divide Eq. (9) by this factor 2. The reader should notice that the CDI requirement derived in Eq. (9) reduces to Eq. (4) in [4] for the special case where the feature of interest is half of the FOVCDI, i.e., our feature is isolated or we use a tight support around the feature [22].

As imaging criterion we propose

SNReff5,
as suggested by the Rose criterion [23], the implications of using a 3σ criterion are described in [appendixB]Appendix B. We consider for example a feature of 20 nm (σ = 10 nm) in an object covering a 0.5 × 0.5 µm2 area, using a perfect coherent illumination with 1012 photons per image at an energy of 4 keV. In order to achieve the desired resolution with PM, we require fw to be smaller or equal to the feature size (20 nm). Assuming a Gaussian beam distribution with fw = 10 nm at 4 keV, the beam waist at a distance of z1 ~ 12.6 µm defines the FOVPM = 0.5 µm covering the whole object. For our PM geometry with big magnification z2z1 as shown in Fig. 1(a), zz1 = 12.6 µm. For this PM scenario, |A| ≈ 0.16 and taking a sampling in real space of a third of the feature size (ps = 0.67 nm) as suggested in [24], ω ≈ 0.14. Therefore from Eq. (8) the SNReffPM0.12NS. Using the detectability threshold in Eq. (10) we impose a condition over the number of scattered photons NSPM1800 photons. Using Eq. (6), the achievable phase sensitivity (ϕmax) in the described PM geometry for a feature of 20 nm is ϕmaxPM3 mrad.

Analogously for CDI, the focusing requirement is relaxed to two times the sample size (FOVCDI = 1 µm), in order to fulfill the solution criterion for the iterative phase retrieval algorithms [19]. Conversely, PM does not require this sampling constraint. From Eqs. (9) and (10) we can obtain the condition for the number of scattered photons for CDI NSCDI1.6104 photons. Thus the achievable sensitivity is ϕmaxCDI7 mrad.

3. Simulation and validation

In order to numerically validate the sensitivity calculations for both methods with our model, we create a pure-phase phantom. This phantom has a background support with a ϕmax = 10 mrad, which is on the order of magnitude of the phase shift expected for a biological sample in water or ice at multi-keV X-rays [25], covering approximately a ~ 0.5 × 0.5 µm2 area. Inside of this object we add three Gaussian scatterers, as depicted in Fig. 2(a). The values of the phase shifts (ϕmax) of the scatterers are chosen according to the values calculated with our imaging criterion.

 figure: Fig. 2

Fig. 2 (a) Simulated phantom with a 10 mrad phase background support. Inside of it we have located three Gaussian scatterers of σ = 10 nm and ϕmax from left to right of (3, 7, 11) mrad, respectively, the gray scale encodes the phase map and the red bar corresponds to 200 nm. The continuous (dashed) box represents the FOV for CDI (PM). We display also the reconstruction for PM (b) and CDI (c) over the region of interest.

Download Full Size | PDF

We simulate both imaging geometries with the above discussed FOVs at the object plane and the same sampling in real space (ps). Using the projection approximation to describe the object, paraxial propagation [26], and Poissonian noise, we simulate the intensities on the detector. For PM we consider that the focal spot has a finite size, therefore we convolve our intensity pattern with the source size. To retrieve the phases from the PM images, we use phase retrieval based on contrast transfer function (CTF) algorithms [12, 13] with a single distance input. For CDI images, we have averaged over 20 reconstructions from different random seeds (starting guess) performed in 10 series alternating 45 hybrid input output algorithm (HIO) with 5 iterations of error reduction algorithm (ER) [27, 28], each with a tight support. Figures 2(b) and (c), show the retrieved phase of the phantom for PM and CDI respectively.

To evaluate if each feature has been properly imaged, we compute the Fourier Ring Correlation (FRC) [29] with the half bit threshold criterion [24], as implemented in [30], between the reconstructed objects and the reference object. The resolution values are reported in Fig. 3 as a function of ϕmax of nine features included in distinct simulations. The horizontal lines represent the resolution thresholds which we use to discriminate between successful and unsuccessful reconstruction of a feature. For CDI, we set the threshold at 2σ = 20 nm. For PM, we correct the threshold to (2σ)2+fw2=23 nm to account for the source size.

 figure: Fig. 3

Fig. 3 Resolution as a function of the maximum phase shift in the sample (ϕmax) for PM and CDI using FRC with half bit threshold criterion. We have computed the FRC of each Gaussian scatterer with a square from [−5σ,5σ ] for PM and CDI with our phantom image and an analogous phantoms with features with a phase shift of 1, 2, 5, 6, 9, and 13 mrad. The resolution for PM (CDI) is represented with square (circle) markers. The expected resolution of 23 and 20 nm is represented by the horizontal dashed and continuous lines for PM and CDI, respectively.

Download Full Size | PDF

Equations (8) and (9) predict sensitivity thresholds ϕmaxPM3 mrad and ϕmaxCDI7 mrad, respectively, which means that in Fig. 3 full square PM data points should be below or compatible with the horizontal dashed line (ϕmaxPM3), while for CDI the full circle points (ϕmax7) should be below or compatible with the continuous horizontal line. The asymmetric error bars are due to the interpolation of the discrete FRC. We therefore note a discrepancy in the sensitivity thresholds for both PM and CDI, which we attribute to the non-perfect efficiency of the phase retrieval algorithm. The reader should notice that we have not included the efficiency of the phase retrieval algorithms in our theoretical model. This factor is out of the scope of this work because it is dependent on the sample, experimental uncertainties, and on the amount of prior knowledge that is brought to bear in the reconstruction procedure. Our result can be interpreted as a best case scenario with a fully efficient phase retrieval algorithm. The relevant prediction that PM can image weaker features than CDI remains valid. However, the data points indicate that for resolvable phase shifts CDI can achieve a better resolution, well below the feature size, not possible in PM because of the source extent.

4. Application to synchrotron and FEL experiments

In this section, we study the application and implications of our criterion for FEL and and synchrotron. For single pulse imaging with FEL [5] the radiation damage does not play a role. We study the sensitivity for both techniques as a function of the desired resolution. For this calculation we simulate a realistic geometry for both setups, neglecting any experimental limitation (achievable fw, sample positioning precision), with a sample size of 0.5 µm size, uniformly illuminated by 1012 photons, with features of the desired resolution. The results of this calculations, for an energy of 4 keV, using Eqs. (6), (8), (9), and (10) are summarized in Fig. 4 (Fig. 6 in [appendixB]Appendix B shows an analogous calculation using a 3σ criterion for the SNReff).

 figure: Fig. 4

Fig. 4 Best sensitivity as a function of the feature size (2σ) for 1012 photons uniformly distributed over the whole FOV. The dashed, continuous, and dotted-dashed lines represent the best sensitivity for PM, CDI, and the criterion of [4], respectively.

Download Full Size | PDF

Conversely, for synchrotron experiments, where the radiation damage plays a crucial role, this model can be used to evaluate the fluence required to image certain scatterers (fixing the scattering cross section) at a certain resolution in a realistic geometry for PM and CDI. To illustrate this we use our Gaussian model, with a maximum thickness t0 = 2σ, to evaluate scatterers given by the protein model in vacuum used in [4] with the corresponding size to the desired resolution at 4 keV, inside a support of 0.5 µm (like our example). We have neglected any technical limitation to achieve the necessary focal spot for each resolution and the focus to sample distance (z1) for PM. From the results shown in Fig. 5, one can see that PM requires less fluence than CDI in these imaging scenarios (the same conclusions can be extracted from Fig. 7 in [appendixB]Appendix B for SNReff = 3).

 figure: Fig. 5

Fig. 5 Required imaging fluence as a function of the feature size (2σ). The dashed, continuous, and dashed-dotted lines represent the required fluence for resolution for PM, CDI, and the criterion of [4], respectively. The horizontal dashed line represents a typical order for the fluence in a single FEL shot.

Download Full Size | PDF

5. Conclusions

In summary, we have proposed a criterion based on a SNR threshold which predicts whether a feature of given size and scattering strength, placed inside a larger object, can be properly retrieved with PM and CDI imaging methodologies. This is useful to design imaging experiments and feasibility studies at FELs and synchrotron sources. Simulations of the experiments provide a qualitative validation of the criterion. In contrast to previous suggestions, our criterion explicitly accounts for the size of the full object, and predicts deterioration of the imaging performance with increasing object size. PM is more suitable to identify weaker features than CDI, although the latter has the potential to provide better resolution as it overcomes the effects of the finite source extension.

Appendix A Signal-to-noise calculations

In this appendix we report the calculation of the signal-to-noise ratio (SNR) for our Gaussian scatter model for coherent diffraction imaging (CDI) and projection microscopy (PM).

Describing our the transmissivity as in Eq. (1)

t(x,y)=ej(ϕ¯+Δϕ(x,y))ejϕ¯(1+jΔϕ(x,y)),
where ϕ¯ is the average phase of the object and ∆ϕ (x,y) is the variation of the phase along the different positions over the field of view (FOV). We have assumed a weakly scattering object ∆ϕ ≪ 1, given by a Gaussian scatterer
Δϕ(x,y)=ϕmaxe(x2+y2)2σ2,
where ϕmax is the maximum phase acquired by the wave front after crossing the scatterer and σ is the scatterer width. Therefore the wave front after our scatter, assuming projection approximation, is given by
ψ(x,y)Φ(1+jϕmaxe(x2+y2)2σ2),
as a function of the incident fluence Φ and neglecting the global phase.

CDI signal-to-noise Ratio

In the Fraunhofer approximation the propagated wave is given by

ψ(x,y;z)=ejkzejk2z(x2+y2)jλz+ψ(εx,εy)ej2πλz(xεx+yεy)dεxdεy,
where λ is the wavelength, k = 2π/λ is the wavenumber, z is the propagating distance between the sample and the detector over the optical axis, and x and y are the detector coordinates. We obtain propagating our wavefront, Eq. (13), and neglecting global phase factors
ψ(x,z;z)=Φ{δD(x,y)+jϕmax2πσ2λzeσ22((kxz)2+(kyz)2)}.

As we are interested to study the scattered signal we will study the intensity out of the center (x ≠ 0 and y ≠ 0)

I(qx,qy)=Φps2(|ϕmax|2πσ2λzeσ2(qx2+qy2)2)2=Nsω(2πNFeσ2(qx2+qy2)2)2,
where qx = kx/z, qy = ky/z, ps is our sampling, NF = σ2/(λz) is the Fresnel number, ω = (ps/σ)2/π is related to the ratio of our sampling and the Gaussian width, and NS is the total number of scattered photons. We have use the fact that the total number of scattered photons is given by NS = ΦσS, where σS is the total scattering cross section given by
σS=+|1t(x,y)|2dxdy=πσ2|ϕmax|2.

We have assumed for simplicity that our intensity is constant within each sampling area.

The intensity for CDI can also be written as a function of the sampling solid angle,

4πΩs=ps2z2=Δqs2k2=λ2FOV2,
where ∆qS = 2π/FOV is the Shannon sampling. Therefore the intensity can be written as
I(qx,qy)=Φ(|ϕmax|2πσ2FOVeσ2(qx2+qy2)2)2.

Thus, we calculate the CDI SNR for the scattering signal

SNR(qx,qy)=I(qx,qy)I(qx,qy)=NSω(2πNFeσ2(qx2+qy2)2)=NS2πσFOVeσ2(qx2+qy2)2

PM signal-to-noise ratio

Now we calculate the propagated field after a distance z close to the object in the Fresnel approximation. Thus neglecting global phase factors

ψ(x,y;z)=Φjλz(1+jΔϕ(εx,εy))ejk(εxx)2+(εyy)22zdεxdεy=Φ(1+jϕmaxAex2+y22σ2A),
where the parameter A is given by
A=11+jzλ2πσ2=11+j12πNF=|A|ejϕA,
and the phase distribution in 2D (∆ϕ (x,y)) is given by Eq. (12).

This allows us to calculate the number of photons registered per sampling pixel

I(x,y;z)=Φps2(1+|ϕmax|2|A|2e(x2+y2)σ2ReA+2|ϕmax||A|e(x2+y2)2σ2ReAsin(ϕAx2+y22σ2ImA))Φps2(1+2|ϕmax||A|e(x2+y2)2σ2ReAsin(ϕAx2+y22σ2ImA)).

We have neglected high order contribution on ϕmax as we are in the weak-phase approximation. We have assumed that the intensity does not change over the pixel area significantly, this is a good approximation for NF≪1.

The X-ray intensity can be expressed by the sum of a background signal, arising from the non-scattered photons (I0), plus the signal originating from the interaction with the sample (Isig)

I(x,y;z)=I0+Isig(x,y;z),
where I0 is the background component given by
I0=Φps2,
and Isig contains the scattering signal and up to first order in ϕmax is given by
Isig(x,y;z)=2Φps2|ϕmax||A|e(x2+y2)2σ2ReAsin(ϕAx2+y22σ2ImA).

We define our SNR as

SNR(x,y;z)=Isig(x,y;z)I(x,y;z)Isig(x,y;z)I0(x,y;z)=2NSω|A|ex2+y22σ2ReA|sin(ϕAx2+y22σ2ImA)|.

Appendix B 3σ imaging criterion

In this appendix we explore the implications of changing our imaging criterion used in Eq. (10) to a 3σ criterion.

Using the same imaging conditions described in Section 3 and analogous calculations as in Section 4, we calculate the best sensitivity, illuminating with 1012 photons, for FEL experiments, the results are depicted in Fig. 6. We can observe that PM becomes more sensitive than the criterion of [4] for features larger than 50 nm inside of a field of view of 500 µm. On the other hand, our CDI criterion for features smaller than 100 nm achieves values less sensitive than the results obtained in [4]. It must be reminded that different field of views will report different phase sensitivities, which is not the case for the criterion in [4]. Above all, the 3σ criterion reports better phase sensitivity than the values for the 5σ shown in Fig. 4, as expected from Eqs. (8) and (9), because the ϕmax functional dependence with the SNReff for both techniques is given by

ϕmaxSNReff.

 figure: Fig. 6

Fig. 6 Best sensitivity for SNReff = 3 as a function of the feature size (2σ) for 1012 photons uniformly distributed over the whole FOV. The dashed, continuous, and dotted-dashed lines represent the best sensitivity for PM, CDI, and the criterion of [4], respectively.

Download Full Size | PDF

For synchrotron experiments, we evaluate the fluence required to image the features described in Section 4. This calculation is summarized in Fig. 7. According to the criterion in [4] we would be able to resolve with 1012 photons features of 4 nm neglecting the radiation damage threshold. On the other hand, we predict around 10 nm and 20 nm resolution approximately for PM and CDI, respectively. For the range of the study we can see that we require more photons than the predicted by the criterion of [4], in spite of using a 3σ criterion. Above all, the 3σ criterion reports better fluence requirements than the values for the 5σ shown in Fig. 5, because, from Eqs. (8) and (9), the Φ dependence with the SNReff for both techniques is given by

ΦSNReff2.

 figure: Fig. 7

Fig. 7 Required imaging fluence for SNReff = 3 as a function of the feature size (2σ). The dashed, continuous, and dashed-dotted lines represent the required fluence for resolution for PM, CDI, and the criterion of [4], respectively. The horizontal dashed line represents a typical order for the fluence in a single FEL shot.

Download Full Size | PDF

Acknowledgments

We are grateful to Chris Jacobsen, Andreas Menzel, Ana Diaz, Spyridon Gkoumas, and the TOMCAT group for fruitful discussions and comments. Part of this work has been supported by the ERC grant ERC-2012-StG 310005-PhaseX.

References and links

1. J. C. Andrews, F. Meirer, Y. J. Liu, Z. Mester, and P. Pianetta, “Transmission X-Ray microscopy for full-field nano imaging of biomaterials,” Microscopy Research and Technique 74, 671–681 (2011). [CrossRef]  

2. S. Watanabe and E. M. Jorgensen, “Visualizing proteins in electron micrographs at nanometer resolution,” Methods Cell. Biol. 111, 286 (2012).

3. D. Shapiro, P. Thibault, T. Beetz, V. Elser, M. Howells, C. Jacobsen, J. Kirz, E. Lima, H. Miao, A. M. Neiman, and D. Sayre, “Biological imaging by soft x-ray diffraction microscopy,” PNAS 102, 15343–15346 (2005). [CrossRef]   [PubMed]  

4. M. R. Howells, T. Beetz, H. N. Chapman, C. Cui, J. M. Holton, C. J. Jacobsen, J. Kirz, E. Lima, S. Marchesini, H. Miao, D. Sayre, D. A. Shapiro, J. C. H. Spence, and D. Starodub, “An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy,” J. of Electron Spectroscopy and Related Phenomena 170, 4–12 (2009). [CrossRef]  

5. R. Neutze, R. Wouts, D. van der Spoel, E. Weckert, and J. Hajdu, “Potential for biomolecular imaging with femtosecond X-ray pulses,” Nature 406, 752–757 (2000). [CrossRef]   [PubMed]  

6. J. Miao, P. Charalambous, J. Kirz, and D. Sayre, “Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens,” Nature 400, 342–344 (1999). [CrossRef]  

7. S. C. Mayo, P. R. Miller, S. W. Wilkins, T. J. Davis, D. Gao, T. E. Gureyev, D. Paganin, D. J. Parry, A. Pogany, and A. W. Stevenson, “Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging,” J. Microsc. 207, 79–96 (2002). [CrossRef]   [PubMed]  

8. O. Hignette, P. Cloetens, G. Rostaing, P. Bernard, and C. Morawe, “Efficient sub 100 nm focusing of hard x rays,” Rev. Sci. Instrum. 76, 1–5 (2005). [CrossRef]  

9. R. Mokso, P. Cloetens, E. Maire, W. Ludwig, and J. Y. Buffìre, “Nanoscale zoom tomography with hard x rays using Kirkpatrick-Baez optics,” Appl. Phys. Lett. 90, 2005–2008 (2007). [CrossRef]  

10. M. Bartels, M. Krenkel, J. Haber, R. N. Wilke, and T. Salditt, “X-Ray Holographic Imaging of Hydrated Biological Cells in Solution,” Phys. Rev. Lett. 114, 048103 (2015). [CrossRef]   [PubMed]  

11. D. Gabor, “A new microscopic principle,” Nature 161, 771–778(1948). [CrossRef]  

12. J. P. Guigay, “Fourier-transform analysis of Fresnel diffraction patterns and in-line holograms,” Optik 49, 121–125 (1977).

13. J. Moosmann, R. Hofmann, A. Bronnikov, and T. Baumbach, “Nonlinear phase retrieval from single-distance radiograph,” Opt. Express 18, 25771–25785 (2010). [CrossRef]   [PubMed]  

14. D. Paganin, S. C. Mayo, T. E. Gureyev, P. R. Miller, and S. W. Wilkins, “Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object,” J. of Mic. 1, 33–40 (2002). [CrossRef]  

15. P. Cloetens, W. Ludwig, J. Baruchel, D. Van Dyck, J. Van Landuyt, J. P. Guigay, and M. Schlenker, “Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays,” Appl. Phys. Lett. 75, 2912–2914 (1999). [CrossRef]  

16. J. P. Guigay, M. Langer, R. Boistel, and P. Cloetens, “Mixed transfer function and transport of intensity approach for phase retrieval in the Fresnel region,” Opt. Lett. 32, 1617–1619 (2007). [CrossRef]   [PubMed]  

17. D. Paganin and K. A. Nugent, “Noninterferometric phase imaging with partially coherent light,” Phys. Rev. Lett. 80, 2586–2589 (1998). [CrossRef]  

18. K. Giewekemeyer, S. Krüger, and S. Kalbfleisch, “X-ray propagation microscopy of biological cells using waveguides as a quasipoint source,” Phys. Rev. A 83, 023804 (2011). [CrossRef]  

19. J. R. Fienup, “Phase retrieval algorithms: a comparison,” Appl. Opt. 21, 2758–2769 (1982). [CrossRef]   [PubMed]  

20. D. Paganin, Coherent X-Ray Optics(Oxford, 2006). [CrossRef]  

21. A. Pogany, D. Gao, and S. W. Wilkins, “Contrast and resolution in imaging with a microfocus x-ray source,” Rev. Sci. Instrum. 68, 2774–2782 (1997). [CrossRef]  

22. A. Schropp and C. G. Schroer, “Dose requirements for resolving a given feature in an object by coherent x-ray diffraction imaging,” New J. of Phys. 12, 35016 (2010). [CrossRef]  

23. A. Rose, “A unified approach to the performance of photographic film, television pickup tubes, and the human eye,” J. of the Society of Motion Picture Engineers 47, 273–294 (1946). [CrossRef]  

24. M. Van Heel and M. Schatz, “Fourier shell correlation threshold criteria,” J. of Structural Biology 151, 250–262 (2005). [CrossRef]  

25. E. Lima, A. Diaz, M. Guizar-Sicairos, S. Gorelick, P. Pernot, T. Schleier, and A. Menzel, “Cryo-scanning X-ray diffraction microscopy of frozen-hydrated yeast,” J. Micropsc. 249, 1–7 (2013). [CrossRef]  

26. M. Born and E. Wolf, Principles of Optics (Pergamon Press, 1999). [CrossRef]  

27. J. R. Fienup, “Iterative method applied to image reconstruction and to computer-generated holograms,” Proc. SPIE 19(3), 2–13 (1980). [CrossRef]  

28. M. Guizar-Sicairos and J. R. Fienup, “Phase retrieval with Fourier-weighted projections,” J. Opt. Soc. Am. A 25, 701–709 (2008). [CrossRef]  

29. W. O. Saxton and W. Baumeister, “The correlation averaging of a regularly arranged bacterial cell envelope protein,” J. of Mic. 127, 127–138 (1982). [CrossRef]  

30. J. Vila-Comamala, A. Diaz, M. Guizar-Sicairos, A. Mantion, C. M. Kewish, A. Menzel, O. Bunk, and C. David, “Characterization of high-resolution diffractive X-ray optics by ptychographic coherent diffractive imaging,” Opt. Express 19, 21333–21344 (2011). [CrossRef]   [PubMed]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (7)

Fig. 1
Fig. 1 (a) PM setup, z1 is the source to sample distance (~ 10 µm), and z2 is the sample to detector distance (~ 1 m). (b) CDI setup, z is the distance from sample to detector.
Fig. 2
Fig. 2 (a) Simulated phantom with a 10 mrad phase background support. Inside of it we have located three Gaussian scatterers of σ = 10 nm and ϕmax from left to right of (3, 7, 11) mrad, respectively, the gray scale encodes the phase map and the red bar corresponds to 200 nm. The continuous (dashed) box represents the FOV for CDI (PM). We display also the reconstruction for PM (b) and CDI (c) over the region of interest.
Fig. 3
Fig. 3 Resolution as a function of the maximum phase shift in the sample (ϕmax) for PM and CDI using FRC with half bit threshold criterion. We have computed the FRC of each Gaussian scatterer with a square from [−5σ,5σ ] for PM and CDI with our phantom image and an analogous phantoms with features with a phase shift of 1, 2, 5, 6, 9, and 13 mrad. The resolution for PM (CDI) is represented with square (circle) markers. The expected resolution of 23 and 20 nm is represented by the horizontal dashed and continuous lines for PM and CDI, respectively.
Fig. 4
Fig. 4 Best sensitivity as a function of the feature size (2σ) for 1012 photons uniformly distributed over the whole FOV. The dashed, continuous, and dotted-dashed lines represent the best sensitivity for PM, CDI, and the criterion of [4], respectively.
Fig. 5
Fig. 5 Required imaging fluence as a function of the feature size (2σ). The dashed, continuous, and dashed-dotted lines represent the required fluence for resolution for PM, CDI, and the criterion of [4], respectively. The horizontal dashed line represents a typical order for the fluence in a single FEL shot.
Fig. 6
Fig. 6 Best sensitivity for SNReff = 3 as a function of the feature size (2σ) for 1012 photons uniformly distributed over the whole FOV. The dashed, continuous, and dotted-dashed lines represent the best sensitivity for PM, CDI, and the criterion of [4], respectively.
Fig. 7
Fig. 7 Required imaging fluence for SNReff = 3 as a function of the feature size (2σ). The dashed, continuous, and dashed-dotted lines represent the required fluence for resolution for PM, CDI, and the criterion of [4], respectively. The horizontal dashed line represents a typical order for the fluence in a single FEL shot.

Equations (29)

Equations on this page are rendered with MathJax. Learn more.

t ( x , y ) = e j ( ϕ ¯ + Δ ϕ ( x , y ) ) ,
Δ ϕ ( x , y ) = ϕ max e ( x 2 + y 2 ) 2 σ 2 ,
I ( x , y ; z ) = I 0 + I sig ( x , y ; z ) .
S N R P M ( x , y ; z ) = I sig ( x , y ; z ) I ( x , y ; z ) I sig ( x , y ; z ) I 0 2 N S ω | A | e x 2 + y 2 2 σ 2 R e ( A ) | sin ( ϕ A x 2 + y 2 2 σ I m ( A ) ) | ,
A = 1 1 + j 1 2 π N F = | A | e j ϕ A ,
N S = Φ σ S = Φ + | 1 t ( x , y ) | 2 d x d y = Φ π σ 2 | ϕ max | 2 ,
S N R C D I ( q x , q y ) = I ( q x , q y ) = N S 2 π σ FOV CDI e σ 2 ( q x 2 + q y 2 ) 2
SNR eff PM 2 N S ω | A | 2 N S 4 π β 2 σ FOV PM ,
SNR eff CDI N S 2 π σ FOV CDI 2 π π q max 2 0 q max e σ 2 q 2 2 q d q N S 2 σ FOV CDI .
SNR eff 5 ,
t ( x , y ) = e j ( ϕ ¯ + Δ ϕ ( x , y ) ) e j ϕ ¯ ( 1 + j Δ ϕ ( x , y ) ) ,
Δ ϕ ( x , y ) = ϕ max e ( x 2 + y 2 ) 2 σ 2 ,
ψ ( x , y ) Φ ( 1 + j ϕ max e ( x 2 + y 2 ) 2 σ 2 ) ,
ψ ( x , y ; z ) = e j k z e j k 2 z ( x 2 + y 2 ) j λ z + ψ ( ε x , ε y ) e j 2 π λ z ( x ε x + y ε y ) d ε x d ε y ,
ψ ( x , z ; z ) = Φ { δ D ( x , y ) + j ϕ max 2 π σ 2 λ z e σ 2 2 ( ( k x z ) 2 + ( k y z ) 2 ) } .
I ( q x , q y ) = Φ p s 2 ( | ϕ max | 2 π σ 2 λ z e σ 2 ( q x 2 + q y 2 ) 2 ) 2 = N s ω ( 2 π N F e σ 2 ( q x 2 + q y 2 ) 2 ) 2 ,
σ S = + | 1 t ( x , y ) | 2 d x d y = π σ 2 | ϕ max | 2 .
4 π Ω s = p s 2 z 2 = Δ q s 2 k 2 = λ 2 FOV 2 ,
I ( q x , q y ) = Φ ( | ϕ max | 2 π σ 2 FOV e σ 2 ( q x 2 + q y 2 ) 2 ) 2 .
SNR ( q x , q y ) = I ( q x , q y ) I ( q x , q y ) = N S ω ( 2 π N F e σ 2 ( q x 2 + q y 2 ) 2 ) = N S 2 π σ FOV e σ 2 ( q x 2 + q y 2 ) 2
ψ ( x , y ; z ) = Φ j λ z ( 1 + j Δ ϕ ( ε x , ε y ) ) e j k ( ε x x ) 2 + ( ε y y ) 2 2 z d ε x d ε y = Φ ( 1 + j ϕ max A e x 2 + y 2 2 σ 2 A ) ,
A = 1 1 + j z λ 2 π σ 2 = 1 1 + j 1 2 π N F = | A | e j ϕ A ,
I ( x , y ; z ) = Φ p s 2 ( 1 + | ϕ max | 2 | A | 2 e ( x 2 + y 2 ) σ 2 ReA + 2 | ϕ max | | A | e ( x 2 + y 2 ) 2 σ 2 ReA sin ( ϕ A x 2 + y 2 2 σ 2 ImA ) ) Φ p s 2 ( 1 + 2 | ϕ max | | A | e ( x 2 + y 2 ) 2 σ 2 ReA sin ( ϕ A x 2 + y 2 2 σ 2 ImA ) ) .
I ( x , y ; z ) = I 0 + I sig ( x , y ; z ) ,
I 0 = Φ p s 2 ,
I sig ( x , y ; z ) = 2 Φ p s 2 | ϕ max | | A | e ( x 2 + y 2 ) 2 σ 2 ReA sin ( ϕ A x 2 + y 2 2 σ 2 ImA).
SNR ( x , y ; z ) = I sig ( x , y ; z ) I ( x , y ; z ) I sig ( x , y ; z ) I 0 ( x , y ; z ) = 2 N S ω | A | e x 2 + y 2 2 σ 2 ReA | sin ( ϕ A x 2 + y 2 2 σ 2 ImA ) | .
ϕ max SNR eff .
Φ SNR eff 2 .
Select as filters