Abstract
A photoacoustic gas system has been implemented for comparison of the performance of an electronic and an optical microphone as acoustic sensors. Results show a minimum detectable pressure of 79.5 μPa/Hz1/2 for the optical microphone.
© 2019 The Author(s)
PDF ArticleMore Like This
Daichi Fujii, Kazuhide Sato, Kazuyoku Tei, and Shigeru Yamaguchi
Tu3F.2 Conference on Lasers and Electro-Optics/Pacific Rim (CLEO/PR) 2018
X. Q. Lu, Y. Wu, and Y. J. Rao
TuE86 Optical Fiber Sensors (OFS) 2018
Congzhe Zhang, Yuanhong Yang, Yuechuan Lin, Yanzhen Tan, Michael Lengden, Gordon Humphries, Walter Johnstone, Hoi Lut Ho, and Wei Jin
WF17 Optical Fiber Sensors (OFS) 2018