Abstract
The differential absorption lidar (DIAL) technique potentially has the ability to measure a wide range of atmospheric gases and industrial pollutants. The mobile DIAL facility developed at the National Physical Laboratory (NPL) is capable of range-resolved measurements of gases such as SO2, NO, NO2 and O3 in the troposphere [1] using visible and ultraviolet radiation. However, there is widespread interest in measuring a much broader range of gaseous pollutants which are emitted in industrial processes. These gases generally have absorption spectra in the infrared spectral region (wavelength range 2–15 μm), where DIAL measurements are much more difficult to carry out. Research aimed at developing a high-energy tunable infrared DIAL source for this requirement is outlined below. The wavelength coverage of the ultraviolet source in the DIAL facility has also been extended to address different atmospheric gases, and examples of results obtained using the NPL simultaneous infrared/ultraviolet DIAL system will be presented.
© 1990 Optical Society of America
PDF ArticleMore Like This
Barrie W Jolliffe, Elizabeth Michelson, Nigel R Swann, and Peter T Woods
MB3 Laser and Optical Remote Sensing: Instrumentation and Techniques (LORS) 1987
C. LAURENCE KORB and BRUCE M. GENTRY
CWK3 Conference on Lasers and Electro-Optics (CLEO:S&I) 1990
R.D. Haskins and L.D. Kaplan
MD9 Optical Remote Sensing of the Atmosphere (ORS) 1990