Abstract
In this work we introduce an analytical way of computing the photon measurement density functions in multilayered flat and spherical media. Comparisons with Monte Carlo simulations in the particular case of two-layered media show very good agreement (differences below 10%), with the additional advantage that the time taken by the theoretical calculations is several orders of magnitude (more than 6) lower than the corresponding Monte Carlo calculations.
© 2023 SPIE
PDF ArticleMore Like This
Demián A. Vera, Héctor A. García, Nicolás A. Carbone, María V. Waks-Serra, Daniela I. Iriarte, and Juan A. Pomarico
126281X European Conference on Biomedical Optics (ECBO) 2023
Christian Blum, Philipp Hank, André Liemert, Simeon Geiger, and Alwin Kienle
126281I European Conference on Biomedical Optics (ECBO) 2023
Federico Tommasi, Angelo Sassaroli, Lorenzo Fini, Stefano Cavalleri, Ernesto Pini, Lorenzo Pattelli, and Fabrizio Martelli
126282I European Conference on Biomedical Optics (ECBO) 2023