Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Method to eliminate pseudoscopic issue in an integral imaging 3D display by using a transmissive mirror device and light filter

Not Accessible

Your library or personal account may give you access

Abstract

We propose an optical method to eliminate pseudoscopic issue in the integral imaging three-dimensional (3D) display by using a transmissive mirror device (TMD) and a light filter. Object light rays passing through the TMD can form an undistorted and depth inverted real image. Therefore, the TMD can eliminate the pseudoscopic issue existing in the traditional integral imaging. However, two ghost images appeared in integral imaging using the TMD. After studying the causes of the ghost images, a light filter is designed and fabricated to eliminate the ghost images. Integral imaging using TMD is developed, and it presents a high quality 3D image without a pseudoscopic issue.

© 2020 Optical Society of America

Full Article  |  PDF Article
More Like This
System to eliminate the graininess of an integral imaging 3D display by using a transmissive mirror device

Han-Le Zhang, Xiao-Li Ma, Xing-Yu Lin, Yan Xing, and Qiong-Hua Wang
Opt. Lett. 47(18) 4628-4631 (2022)

Depth of field and resolution-enhanced integral imaging display system

Xiao-Li Ma, Han-Le Zhang, Rong-Ying Yuan, Tong-Yu Wang, Min-Yang He, Yan Xing, and Qiong-Hua Wang
Opt. Express 30(25) 44580-44593 (2022)

High-quality 3D display system for an integral imaging microscope using a simplified direction-inversed computation based on user interaction

Ki-Chul Kwon, Munkh-Uchral Erdenebat, Anar Khuderchuluun, Ki Hoon Kwon, Min Young Kim, and Nam Kim
Opt. Lett. 46(20) 5079-5082 (2021)

Supplementary Material (2)

NameDescription
Visualization 1       The reconstructed 3D existing the pseudoscopic issue.
Visualization 2       The reconstructed 3D without the pseudoscopic issue.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (6)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.