Abstract

A compact dual-cavity Fabry–Perot interferometer (DC-FPI) sensor is proposed and demonstrated based on a hollow-core photonic bandgap fiber (HC-PBF) spliced with a hollow-core fiber (HCF). The HC-PBF, which has low transmission loss, was used as the first FPI cavity and also acted as a bridge between the lead-in single-mode fiber and the HCF. The HCF was used as the second FPI cavity and also acted as a micro gas inlet into the first FPI cavity. A DC-FPI sensor with different cavity lengths of 226 and 634 μm in the first FPI and the second FPI was created. Both gas pressures ranging from 0–10 MPa and temperatures ranging from 100–800°C were measured using the DC-FPI sensors together with a fast Fourier transform and phase-demodulation algorithm. Experimental results showed that the first FPI cavity was gas pressure sensitive but temperature insensitive, while the second FPI cavity was temperature sensitive but gas pressure insensitive. A high gas pressure sensitivity of 1.336 μm/MPa and a temperature sensitivity of 17 nm/°C were achieved in the DC-FPI sensor. Moreover, the cross sensitivity between the gas pressure and temperature was calculated to be 15  Pa/°C and 0.3°C/MPa. The proposed DC-FPI sensors provide a promising candidate for the simultaneous measurement of high pressures and high temperatures at some precise locations.

© 2018 Optical Society of America

Full Article  |  PDF Article
OSA Recommended Articles
Hollow-core fiber Fabry–Perot photothermal gas sensor

Fan Yang, Yanzhen Tan, Wei Jin, Yuechuan Lin, Yun Qi, and Hoi Lut Ho
Opt. Lett. 41(13) 3025-3028 (2016)

Simultaneous measurement of pressure and temperature by employing Fabry-Perot interferometer based on pendant polymer droplet

Bing Sun, Yiping Wang, Junle Qu, Changrui Liao, Guolu Yin, Jun He, Jiangtao Zhou, Jian Tang, Shen Liu, Zhengyong Li, and Yingjie Liu
Opt. Express 23(3) 1906-1911 (2015)

Batch-producible MEMS fiber-optic Fabry–Perot pressure sensor for high-temperature application

Pinggang Jia, Hao Liang, Guocheng Fang, Jiang Qian, Fei Feng, Ting Liang, and Jijun Xiong
Appl. Opt. 57(23) 6687-6692 (2018)

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Equations (4)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Metrics

You do not have subscription access to this journal. Article level metrics are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription