Abstract
In this Letter we report on the fabrication and testing of an extremely thin variable aperture stop based on the design of a single chamber adaptive membrane lens with integrated actuation. The aperture consists of a ring-shaped piezoelectric bending actuator with an elastic silicone membrane in the center. The formed cavity is filled with a nontransparent fluid and sealed with a glass platelet. In a voltage range up to , an opening of the aperture of in diameter is obtained. The transmission in comparison to a standard mechanical aperture stop is maximum 6% lower.
© 2011 Optical Society of America
Full Article | PDF ArticleMore Like This
Seung Tae Choi, Jeong Yub Lee, Jong Oh Kwon, Seungwan Lee, and Woonbae Kim
Opt. Lett. 36(10) 1920-1922 (2011)
Zenghong Duan, Lihui Wang, Zhi Li, Jian Fu, Susheng Fu, Boqian Chen, Yuxun Chen, and Yong Zhao
Appl. Opt. 62(17) 4609-4617 (2023)
Hyunhwan Choi, Dong Seok Han, and Yong Hyub Won