Abstract
We describe how two-wave mixing of light scattered at the entrance face of a photorefractive crystal can be used to measure the frequency difference between two independent lasers. This method can be used to accomplish initial frequency acquisition in coherent optical homodyne receivers.
© 1994 Optical Society of America