Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Suppression of flicker response with increasing test illuminance: roles of temporal waveform, modulation depth, and frequency

Not Accessible

Your library or personal account may give you access

Abstract

This study examined the detectability of flicker for small foveal long-wavelength test stimuli centered within surrounding long-wavelength annular adaptation stimuli. Flicker threshold-versus-illuminance (tvi) curves were analyzed for four different test-stimulus waveforms—sine-wave, square-wave, and rapid-on sawtooth and rapid-off sawtooth flicker—at temporal frequencies ranging from 12 to 21 Hz and at temporal modulation depths ranging from ~50% to 100%. For all stimulus combinations that were examined involving temporal frequencies above 12 Hz, the resultant flicker tvi curves shared the following characteristic features: First, at operationally dim surround illuminances, there was always a single elevated threshold for detection of flicker. Second, some surround illuminance always could be found for which flicker threshold decreased abruptly, typically by ~1.5 log units within 0.1 log unit of surround illuminance increase. Third, when test illuminance was incremented above this lower flicker threshold, flicker always vanished; when test illuminance was incremented still further, flicker reappeared. Finally, at sufficiently bright surround illuminances flicker did not disappear with increasing test illuminance. Although these effects held for all waveforms, the abrupt decrease of flicker threshold occurred at brighter surround illuminances for sawtooth than for sine-wave flicker, and at brighter surround illuminances for sine-wave than for square-wave flicker, at least for fully modulated waveforms (of a given temporal frequency). Moreover, when modulation depth was adjusted so that any two different waveforms had the same first-harmonic contrast, the resultant flicker tvi curves became identical when plotted as first-harmonic amplitude versus surround illuminance. This identity held for any given temporal frequency, even though the flicker tvi curves for 12–Hz fully modulated sine-wave or square-wave flicker did not manifest flicker response suppression, whereas the flicker tvi curves for sawtooth flicker did. These and other results imply that the first-harmonic contrast of the test stimulus fully determines the shape of the entire flicker tvi curve and that the dc component of the test stimulus helps to cause flicker response suppression. The results also demonstrate that first-harmonic equivalence is only a necessary, not a sufficient, condition for linearity.

© 1995 Optical Society of America

Full Article  |  PDF Article
More Like This
Equivalence between temporal frequency and modulation depth for flicker response suppression: analysis of a three-process model of visual adaptation

Alvin Eisner, Arthur G. Shapiro, and Joel A. Middleton
J. Opt. Soc. Am. A 15(8) 1987-2002 (1998)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (7)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.