Factors of Merit for Radiation Detectors

Not Accessible

Your library or personal account may give you access

Abstract

In Part I, the need for a suitably defined factor of merit for comparing the sensitivity of different radiation detectors is explained (Section 1). Both the advantages and the very important limitations of such a factor of merit are discussed.

In Section 2, separate factors of merit for Type I and Type II detectors are defined. The factor of merit for Type I detectors is defined as the ratio of the noise equivalent power given by the fundamental limit defined in Paper I to the noise equivalent power actually measured in the reference condition. The factor of merit for Type II detectors is similarly defined in terms of the actual noise equivalent power in the reference condition and the empirically determined minimum value for the noise equivalent power proposed by R. J. Havens. Section 3 contains a brief discussion of the significance of the factor of merit for the special case of the bolometer.

In Part II, the noise equivalent power in the reference condition, and the factor of merit is determined for about fifty thermocouples and bolometers. The results are presented in Tables I and II, and in Figs. 1 and 2. A description of each detector is given in Section 5, along with a statement of any special calculations which were necessary.

All of the results presented are based on measurements made by other persons; no measurements were performed by the writer. The sources of information are described in Section 3.

An Appendix is provided whose purpose is to call attention to the wide variety of possibilities in the specification of the relevant properties of radiation detectors, and thereby to encourage precision in the statement of these properties in the future periodical literature.

© 1949 Optical Society of America

Full Article  |  PDF Article
More Like This
A New Classification System for Radiation Detectors*

R. Clark Jones
J. Opt. Soc. Am. 39(5) 327-343 (1949)

The Ultimate Sensitivity of Radiation Detectors

R. Clark Jones
J. Opt. Soc. Am. 37(11) 879-890 (1947)

On the Ultimate Sensitivity and Practical Performance of Radiation Detectors

P. B. Fellgett
J. Opt. Soc. Am. 39(11) 970-976 (1949)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (2)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (20)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved