Utility of near infrared spectrophotometry in mesenteric ischemia: An experimental study

Not Accessible

Your library or personal account may give you access

Abstract

This study investigated the effectiveness of near infrared (NIR) spectrophotometry for measuring abdominal saturation in a rat model of induced mesenteric ischemia. This was a randomized, controlled, non-blinded interventional animal study. Twenty-eight male Sprague Dawley rats were randomly allocated into four groups. Following induction of anesthesia, the abdominal region was shaved and intra-abdominal access was achieved through a 4-cm midline incision and basal measurements were performed using an INVOS-5100c device. The rats were grouped on the basis of rSO2 measurement times. Mesenteric artery ligation was not performed on the control group rats. From the rest of the mesenteric artery ligated rats, measurements were taken at 30 min, at 2 h and at 6 h. Measurements were repeated using NIR spectrophotometry probes after the abdomen was surgically closed. Following the measurements, the abdomen was re-opened and small intestine tissue specimens were taken for histopathological examination. Initial and final NIR spectrophotometry measurements were compared. No statistically significant difference was found in the group 1 between basal rSO2 values and post-incision values (p = 0.748). There was a significant variation between the initial and final measurements in groups 2, 3, and 4 (p = 0.018). Although various radiological or biochemical markers are available for detecting mesenteric ischemia, the use of NIR spectrophotometry can be considered a good non-invasive alternative method for early diagnosis of acute mesenteric ischemia.

© 2018 The Author(s)

PDF Article
More Like This
New multichannel near infrared spectrophotometry system for functional studies of the brain in adults and neonates

Daniel Haensse, Peter Szabo, Derek Brown, Jean-Claude Fauchère, Peter Niederer, Hans-Ulrich Bucher, and Martin Wolfa
Opt. Express 13(12) 4525-4538 (2005)

Do GSM 900MHz signals affect cerebral blood circulation? A near-infrared spectrophotometry study

Martin Wolf, Daniel Haensse, Geert Morren, and Juerg Froehlich
Opt. Express 14(13) 6128-6141 (2006)

Assessment of the brain ischemia during orthostatic stress and lower body negative pressure in air force pilots by near-infrared spectroscopy

Anna Gerega, Stanislaw Wojtkiewicz, Piotr Sawosz, Michal Kacprzak, Beata Toczylowska, Karolina Bejm, Franciszek Skibniewski, Aleksander Sobotnicki, Adam Gacek, Roman Maniewski, and Adam Liebert
Biomed. Opt. Express 11(2) 1043-1060 (2020)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved