Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Non-uniformity correction of polarization response for liquid crystal modulated polarimeters

Not Accessible

Your library or personal account may give you access

Abstract

Liquid crystal modulated polarimeters (LCMPs) are often used to detect the full polarization information of target scenes. In this study, a non-uniformity correction method based on reference source calibration for LCMP is proposed. We analyze the error sources of the polarimeter and establish a grayscale response model with non-uniformity noises. The gain and bias correction coefficient of each pixel is calculated based on the linear response property of the detector. The polarization parameters of each detection unit of the uniform light source with the same polarization state calculated by the corrected Stokes vector are uniform. Results show that the error of the degree of linear polarization is reduced by 5.08%, and the degree of circular polarization is reduced by 19%. Therefore, the proposed method effectively improves the non-uniformity and detection accuracy of polarimeters.

© 2019 Optical Society of America

Full Article  |  PDF Article
More Like This
Non-uniformity correction for division of focal plane polarimeters with a calibration method

Junchao Zhang, Haibo Luo, Bin Hui, and Zheng Chang
Appl. Opt. 55(26) 7236-7240 (2016)

Temporal and spatial error model for estimating the measurement precision of the division of focal plane polarimeters

Jie Yang, Su Qiu, Weiqi Jin, and Fuduo Xue
Opt. Express 29(13) 20808-20828 (2021)

Optimal design for a broadband Stokes polarimeter of liquid crystal variable retarders

Jiaxin Wu, Yanqiu Li, Tianlei Ning, Chenhui Long, and Guodong Zhou
Appl. Opt. 61(25) 7490-7497 (2022)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (7)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (5)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (28)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.