Abstract
This paper reports for the first time, to the best of our knowledge, on the simultaneous imaging of the gas-phase temperature and fuel vapor mass fraction distribution in a direct-injection spark-ignition (DISI) spray under engine-relevant conditions using tracer planar laser-induced fluorescence (TPLIF). For measurements in the spray, the fluorescence tracer 3-pentanone is added to the nonfluorescent surrogate fuel iso-octane, which is excited quasi-simultaneously by two different excimer lasers for two-line excitation LIF. The gas-phase temperature of the mixture of fuel vapor and surrounding gas and the fuel vapor mass fraction can be calculated from the two LIF signals. The measurements are conducted in a high-temperature, high-pressure injection chamber. The fluorescence calibration of the tracer was executed in a flow cell and extended significantly compared to the existing database. A detailed error analysis for both calibration and measurement is provided. Simultaneous single-shot gas-phase temperature and fuel vapor mass fraction fields are processed for the assessment of cyclic spray fluctuations.
© 2016 Optical Society of America
Full Article | PDF ArticleMore Like This
Michael Storch, Susanne Lind, Stefan Will, and Lars Zigan
Appl. Opt. 55(30) 8532-8540 (2016)
Micha Löffler, Frank Beyrau, and Alfred Leipertz
Appl. Opt. 49(1) 37-49 (2010)
Susanne Lind, Simon Aßmann, Lars Zigan, and Stefan Will
Appl. Opt. 55(7) 1551-1558 (2016)