Abstract
We present an all-fiber design for a microphone using a fiber Bragg grating Fabry–Perot resonator attached to a diaphragm transducer. We analytically model and verify the fiber–diaphragm mechanical interaction, using the Hänsch–Couillaud readout technique to provide necessary sensitivity. We achieved a noise-equivalent strain sensitivity of , which corresponds to a sound pressure of at 1 kHz limited by laser frequency noise and yielding a signal-to-noise ratio of with a 1 Pa drive at 1 kHz, in close agreement with modeled results.
© 2016 Optical Society of America
Full Article | PDF ArticleMore Like This
Xinyu Hu, Yan Yue, Chen Cai, and Zhi-Mei Qi
Appl. Opt. 62(23) 6072-6080 (2023)
Shen Tian, Yingying Qiao, Mu Liang, Mingyang Feng, Yang Gao, Lei Li, and Chongxin Shan
Opt. Express 31(13) 21796-21805 (2023)
Wenjun Ni, Ping Lu, Xin Fu, Wei Zhang, Perry Ping Shum, Handong Sun, Chunyong Yang, Deming Liu, and Jiangshan Zhang
Opt. Express 26(16) 20758-20767 (2018)