Abstract
The Ozone Monitoring Instrument (OMI) overpass solar ultraviolet (UV) indices have been validated against the ground-based UV indices derived from Norwegian Institute for Air Research UV measurements in Kampala (0.31° N, 32.58° E, 1200 m), Uganda for the period between 2005 and 2014. An excessive use of old cars, which would imply a high loading of absorbing aerosols, could cause the OMI retrieval algorithm to overestimate the surface UV irradiances. The UV index values were found to follow a seasonal pattern with maximum values in March and October. Under all-sky conditions, the OMI retrieval algorithm was found to overestimate the UV index values with a mean bias of about 28%. When only days with radiation modification factor greater than or equal to 65%, 70%, 75%, and 80% were considered, the mean bias between ground-based and OMI overpass UV index values was reduced to 8%, 5%, 3%, and 1%, respectively. The overestimation of the UV index by the OMI retrieval algorithm was found to be mainly due to clouds and aerosols.
© 2015 Optical Society of America
Full Article | PDF ArticleMore Like This
Taddeo Ssenyonga, Dennis Muyimbwa, Arne Dahlback, Jakob J. Stamnes, Børge Hamre, Nicolausi Ssebiyonga, and Øyvind Frette
Appl. Opt. 59(31) 9896-9904 (2020)
L. Fan, W. Li, A. Dahlback, J. J. Stamnes, S. Stamnes, and K. Stamnes
Appl. Opt. 54(8) 1945-1951 (2015)
L. Fan, W. Li, A. Dahlback, J. J. Stamnes, S. Englehardt, S. Stamnes, and K. Stamnes
Appl. Opt. 53(17) 3598-3606 (2014)