Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Ultrasensitive, self-calibrated cavity ring-down spectrometer for quantitative trace gas analysis

Not Accessible

Your library or personal account may give you access

Abstract

A cavity ring-down spectrometer is built for trace gas detection using telecom distributed feedback (DFB) diode lasers. The longitudinal modes of the ring-down cavity are used as frequency markers without active-locking either the laser or the high-finesse cavity. A control scheme is applied to scan the DFB laser frequency, matching the cavity modes one by one in sequence and resulting in a correct index at each recorded spectral data point, which allows us to calibrate the spectrum with a relative frequency precision of 0.06 MHz. Besides the frequency precision of the spectrometer, a sensitivity (noise-equivalent absorption) of 4×1011cm1Hz1/2 has also been demonstrated. A minimum detectable absorption coefficient of 5×1012cm1 has been obtained by averaging about 100 spectra recorded in 2  h. The quantitative accuracy is tested by measuring the CO2 concentrations in N2 samples prepared by the gravimetric method, and the relative deviation is less than 0.3%. The trace detection capability is demonstrated by detecting CO2 of ppbv-level concentrations in a high-purity nitrogen gas sample. Simple structure, high sensitivity, and good accuracy make the instrument very suitable for quantitative trace gas analysis.

© 2014 Optical Society of America

Full Article  |  PDF Article
More Like This
Multicomponent gas detection based on concise CW-cavity ring-down spectroscopy with a bow-tie design

Jinduo Wang, Jin Yu, Zeqiang Mo, Jianguo He, Shoujun Dai, Jingjing Meng, Yang Liu, Xue Zhang, and Hong Yi
Appl. Opt. 58(11) 2773-2781 (2019)

Real-time ultrasensitive detection of ammonia gas using a compact CRDS spectrometer

Jaebeom Lee and Myoung-Kyu Oh
Appl. Opt. 62(5) 1357-1363 (2023)

Portable cavity ring-down spectrometer for an HO2 radical measurement: instrument’s performance and potential improvement using a narrow linewidth laser

Chunhui Wang, Weixiong Zhao, Bo Fang, Nana Yang, Feihu Cheng, Xiao Hu, Yang Chen, Weijun Zhang, Christa Fittschen, and Weidong Chen
Opt. Express 30(21) 37446-37456 (2022)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (4)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.