Abstract
A novel all-fiber sensing configuration for simultaneous measurements of temperature and strain based on the up-taper Mach–Zehnder interferometer (MZI) with an in-line embedded fiber Bragg grating (FBG) is proposed and experimentally demonstrated. This configuration consists of two up-tapers fabricated by an excessive fusion splicing method and a short segment of inscribed FBG. Due to the different responses of the up-taper MZI and the FBG to the uniform variation of temperature and strain, the simultaneous measurement for these two variables could be achieved by real-time monitoring the transmission spectrum. For 0.01 nm wavelength resolution, a resolution of 0.311°C in temperature can be achieved, and the average strain resolution is 10.07 με.
© 2014 Optical Society of America
Full Article | PDF ArticleMore Like This
Lingya Lv, Sumei Wang, Lan Jiang, Fei Zhang, Zhitao Cao, Peng Wang, Yi Jiang, and Yongfeng Lu
Appl. Opt. 54(36) 10678-10683 (2015)
Jiangtao Zhou, Changrui Liao, Yiping Wang, Guolu Yin, Xiaoyong Zhong, Kaiming Yang, Bing Sun, Guanjun Wang, and Zhengyong Li
Opt. Express 22(2) 1680-1686 (2014)
Junjie Zhu, Wei He, Shaode Li, Zhihan Li, and Lianqing Zhu
Appl. Opt. 62(25) 6661-6671 (2023)