Digital camera measurements of soot temperature and soot volume fraction in axisymmetric flames

Not Accessible

Your library or personal account may give you access

Abstract

New diagnostics are presented that use a digital camera to measure full-field soot temperatures and soot volume fractions in axisymmetric flames. The camera is a Nikon D700 with 12 megapixels and 14 bit depth in each color plane, which was modified by removing the infrared and anti-aliasing filters. The diagnostics were calibrated with a blackbody furnace. The flame considered here was an 88 mm long ethylene/air co-flowing laminar jet diffusion flame on a round 11.1 mm burner. The resolution in the flame plane is estimated at between 0.1 and 0.7 mm. Soot temperatures were measured from soot radiative emissions, using ratio pyrometry at 450, 650, and 900 nm following deconvolution. These had a range of 1600–1850 K, a temporal resolution of 125 ms, and an estimated uncertainty of ±50K. Soot volume fractions were measured two ways: from soot radiative emissions and from soot laser extinction at 632.8 nm, both following deconvolution. Soot volume fractions determined from emissions had a range of 0.1–10 ppm, temporal resolutions of 125 ms, and an estimated uncertainty of ±30%. Soot volume fractions determined from laser extinction had a range of 0.2–10 ppm, similar temporal resolutions, and an estimated uncertainty of ±10%. The present measurements agree with past measurements in this flame using traversing optics and probes; however, they avoid the long test times and other complications of such traditional methods.

© 2013 Optical Society of America

Full Article  |  PDF Article
More Like This
Thin-filament pyrometry with a digital still camera

Jignesh D. Maun, Peter B. Sunderland, and David L. Urban
Appl. Opt. 46(4) 483-488 (2007)

Two-color laser-induced incandescence (2C-LII) technique for absolute soot volume fraction measurements in flames

Silvana De Iuliis, Francesco Cignoli, and Giorgio Zizak
Appl. Opt. 44(34) 7414-7423 (2005)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (11)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.