Abstract
Avalanche diodes (ADs) are widely used to count photons in quantum interferometry. In reality they do not count photons, but click once when a bunch of photons arrives in a light pulse. We model this behavior in typical quantum optical interferometers like the Hong–Ou–Mandel beam splitter and the Mach–Zehnder interferometer, and compare it with the behavior of the photon-number-resolving (PNR) detector and the Hanbury-Brown–Twiss detector in these measuring devices. Our results show that quantum interferometric measurements with biphotons could be performed with single ADs, if the noise of the diodes could be reduced. Even a single PNR detector can be used in these interferometers, if the variance of the measurement is determined, since it reveals information about biphoton interference in contrast to the single detector counting rate.
© 2012 Optical Society of America
Full Article | PDF ArticleMore Like This
Yi Jian, E Wu, Xiuliang Chen, Guang Wu, and Heping Zeng
Appl. Opt. 50(1) 61-65 (2011)
Gur Lubin, Ron Tenne, Ivan Michel Antolovic, Edoardo Charbon, Claudio Bruschini, and Dan Oron
Opt. Express 27(23) 32863-32882 (2019)
Magued B. Nasr, Olga Minaeva, Gregory N. Goltsman, Alexander V. Sergienko, Bahaa E. A. Saleh, and Malvin C. Teich
Opt. Express 16(19) 15104-15108 (2008)