Abstract
We investigate the use of the Mellin–Laplace transform for reconstructing optical parameters from time-resolved optical tomography in diffusive media. We present here its definition, its mathematical properties, and its sensitivity to variations of optical properties. The method was validated on two-dimensional reconstructions from simulation in the reflection geometry. We conclude that reconstructions based on the Mellin–Laplace transform are more robust to noise than the methods using first moments.
© 2012 Optical Society of America
Full Article | PDF ArticleMore Like This
Judy Zouaoui, Laura Di Sieno, Lionel Hervé, Antonio Pifferi, Andrea Farina, Alberto Dalla Mora, Jacques Derouard, and Jean-Marc Dinten
Biomed. Opt. Express 7(10) 4346-4363 (2016)
Agathe Puszka, Lionel Hervé, Anne Planat-Chrétien, Anne Koenig, Jacques Derouard, and Jean-Marc Dinten
Biomed. Opt. Express 4(4) 569-583 (2013)
Limin Zhang, Feng Gao, Huiyuan He, and Huijuan Zhao
Opt. Express 16(10) 7214-7223 (2008)