Abstract
Active triangulation measurement systems with a rigid geometric configuration are inappropriate for scanning large objects with low measuring tolerances. The reason is that the ratio between the depth recovery error and the lateral extension is a constant that depends on the geometric setup. As a consequence, measuring large areas with low depth recovery error requires the use of multiresolution techniques. We propose a multiresolution technique based on a camera–projector system previously calibrated. The method consists of changing the camera or projector’s parameters in order to increase the system depth sensitivity. A subpixel retroprojection error in the self-calibration process and a decrease of approximately one order of magnitude in the depth recovery error can be achieved using the proposed method.
© 2009 Optical Society of America
Full Article | PDF ArticleMore Like This
Guan Xu, Xinyuan Zhang, Jian Su, Xiaotao Li, and Anqi Zheng
Appl. Opt. 55(10) 2653-2656 (2016)
Rui Chen, Jing Xu, Heping Chen, Jianhua Su, Zonghua Zhang, and Ken Chen
Appl. Opt. 55(16) 4293-4300 (2016)
Jing Xu, Rui Chen, Shuntao Liu, and Yong Guan