Simple formulas are often used to estimate the sensitivity of coded mask x-ray or gamma-ray telescopes, but these are strictly applicable only if a number of basic assumptions are met. Complications arise, for example, if a grid structure is used to support the mask elements, if the detector spatial resolution is not good enough to completely resolve all the detail in the shadow of the mask, or if any of a number of other simplifying conditions are not fulfilled. We derive more general expressions for the Poisson-noise-limited sensitivity of astronomical telescopes using the coded mask technique, noting explicitly in what circumstances they are applicable. The emphasis is on using nomenclature and techniques that result in simple and revealing results. Where no convenient expression is available a procedure is given that allows the calculation of the sensitivity. We consider certain aspects of the optimization of the design of a coded mask telescope and show that when the detector spatial resolution and the mask to detector separation are fixed, the best source location accuracy is obtained when the mask elements are equal in size to the detector pixels.

© 2008 Optical Society of America

Full Article  |  PDF Article
More Like This
Imaging x-ray sources at a finite distance in coded-mask instruments

Immacolata Donnarumma, Luigi Pacciani, Igor Lapshov, and Yuri Evangelista
Appl. Opt. 47(19) 3513-3523 (2008)

Geometric coded aperture masks

A. R. Gourlay and J. B. Stephen
Appl. Opt. 22(24) 4042-4047 (1983)

Gamma ray imaging using coded aperture masks: a computer simulation approach

J. Jimenez, Pedro Olmos, J. L. de Pablos, and J. M. Perez
Appl. Opt. 30(5) 549-560 (1991)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (46)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved