Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Determination of the size and structure of an X-pinch x-ray source from the diffraction pattern produced by microfabricated slits

Not Accessible

Your library or personal account may give you access

Abstract

X-pinch plasma emits subnanosecond bursts of x rays in the 3–10-keV energy range from a small source. As such, it has been used for high-resolution point-projection imaging of small, dense, rapidly changing plasmas as well as for submillimeter-thick biological samples. In addition to the effect of source size on geometric resolution, a small source size can also provide high spatial coherence of x rays, enabling the rays to be used for imaging weakly absorbing objects with excellent spatial resolution by a method called phase-contrast imaging. To determine the source size, we microfabricated gold slits and imaged them in a point-projection radiography configuration. The shape of the shadow image pattern depends on the source size and energy band of the x rays, the shape and material used for the slits, and the geometry of the experiment. Experimental results have been compared with wave-optics calculations of the expected image pattern as a function of all the parameters listed above. For example, assuming a Gaussian source distribution, an effective source size in 2.5–4.1 Å radiation (1 Å = 0.1 nm) of 1.2 ± 0.5 µm (full width at half-maximum) was determined for a 20-µm Mo wire X pinch. Characterization of the size and structure of the x-ray bursts from X pinches by the use of different wire materials and different slit structures is made.

© 2005 Optical Society of America

Full Article  |  PDF Article
More Like This
Uniform large-area x-ray imaging at 9 keV using a backlit pinhole

Jonathan Workman, James R. Fincke, George A. Kyrala, and Tim Pierce
Appl. Opt. 44(6) 859-865 (2005)

Efficient, 1–100-keV x-ray radiography with high spatial and temporal resolution

D. K. Bradley, O. L. Landen, A. B. Bullock, S. G. Glendinning, and R. E. Turner
Opt. Lett. 27(2) 134-136 (2002)

Evaluation of bent-crystal x-ray backlighting and microscopy techniques for the Sandia Z machine

Daniel B. Sinars, Guy R. Bennett, David F. Wenger, Michael E. Cuneo, and John L. Porter
Appl. Opt. 42(19) 4059-4071 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (11)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (4)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.