Abstract
A new algorithm for the retrieval of columnar water vapor content is presented. The proposed procedure computes the area of the H2O absorption centered about 940 nm to allow its integrated columnar abundance as well as its density at ground level to be assessed. The procedure utilizes the HITRAN 2000 database as the source of H2O cross-section spectra. Experimental results were derived from radiometrically calibrated hyperspectral images collected by the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) sensor over the Cuprite mining district in Nevada. Numerical simulations based on the MODTRAN 4 radiative transfer code were also employed for investigating the algorithm’s performance. An additional empirical H2O retrieval procedure was tested by use of data gathered by the VIRS-200 imaging spectrometer.
© 2004 Optical Society of America
Full Article | PDF ArticleMore Like This
Bo-Cai Gao, Marcos J. Montes, Ziauddin Ahmad, and Curtiss O. Davis
Appl. Opt. 39(6) 887-896 (2000)
Murugan Karthick, Palanisamy Shanmugam, and Xianqiang He
Opt. Express 32(5) 7659-7681 (2024)
Alessandro Barducci, Francesco Castagnoli, Donatella Guzzi, Paolo Marcoionni, Ivan Pippi, and Marco Poggesi
Appl. Opt. 43(1) 183-195 (2004)