Influence of optical aberrations on laser-induced plasma formation in water and their consequences for intraocular photodisruption

Not Accessible

Your library or personal account may give you access

Abstract

The influence of spherical aberrations on laser-induced plasma formation in water by 6-ns Nd:YAG laser pulses was investigated for focusing angles that are used in intraocular microsurgery. Waveform distortions of 5.5λ and 18.5λ between the optical axis and the 1/e 2 irradiance values of the laser beam were introduced by replacement of laser achromats in the delivery system by planoconvex lenses. Aberrations of 18.5λ increased the energy threshold for plasma formation by a factor of 8.5 compared with the optimized system. The actual irradiance threshold for optical breakdown was determined from the threshold energy in the optimized system and the spot size measured with a knife-edge technique. For aberrations of 18.5λ the irradiance threshold was 48 times larger than the actual threshold when it was calculated by use of the diffraction-limited spot size but was 35 times smaller when it was calculated by use of the measured spot size. The latter discrepancy is probably due to hot spots in the focal region of the aberrated laser beam. Hence the determination of the optical-breakdown threshold in the presence of aberrations leads to highly erroneous results. In the presence of aberrations the plasmas are as much as 3 times longer and the transmitted energy is 17–20 times higher than without aberrations. Aberrations can thus strongly compromise the precision and the safety of intraocular microsurgery. They can further account for a major part of the differences in the breakdown-threshold and the plasma-transmission values reported in previous investigations.

© 1999 Optical Society of America

Full Article  |  PDF Article
More Like This
Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics

Anja Hansen, Romain Géneaux, Axel Günther, Alexander Krüger, and Tammo Ripken
Biomed. Opt. Express 4(6) 852-867 (2013)

Intraocular laser surgical probe for membrane disruption by laser-induced breakdown

Daniel X. Hammer, Gary D. Noojin, Robert J. Thomas, Candace E. Clary, Benjamin A. Rockwell, Cynthia A. Toth, and W. P. Roach
Appl. Opt. 36(7) 1684-1693 (1997)

Experimental investigation on multiple breakdown in water induced by focused nanosecond laser

Lei Fu, Siqi Wang, Jing Xin, Shijia Wang, Cuiping Yao, Zhenxi Zhang, and Jing Wang
Opt. Express 26(22) 28560-28575 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (7)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (6)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved