Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Particle sizing in strongly turbid suspensions with the one-beam cross-correlation dynamic light-scattering technique

Not Accessible

Your library or personal account may give you access

Abstract

The utility of the one-beam cross-correlation dynamic light-scattering system for sizing small particles in suspension was previously limited by its small-intensity signal-to-baseline ratio for strongly turbid suspensions. We describe three improvements in the optical system and sample cell that raise the ratio to a value comparable with that of other cross-correlation dynamic light-scattering systems. These improvements are (i) using a square cross-sectional sample cell to minimize the attenuation of the incident beam and singly scattered light, (ii) placing a 200-µm-wide slit between the sample cell and the detector fibers to mask off the region of weak single scattering and strong multiple scattering from the detectors’ field of view, and (iii) aligning the center of the detectors’ field of view with the region of strongest single scattering. We analyze a number of suspensions of polystyrene latex spheres with a diameter between 65 and 562 nm in water using this improved one-beam instrument and find that the measured radius is determined in a 2-min data collection time to better than ±10% for volume fractions of the suspended polystyrene latex spheres up to a few percent.

© 1999 Optical Society of America

Full Article  |  PDF Article
More Like This
Multiple-scattering suppression by cross correlation

William V. Meyer, David S. Cannell, Anthony E. Smart, Thomas W. Taylor, and Padetha Tin
Appl. Opt. 36(30) 7551-7558 (1997)

Investigation of static structure factor in dense suspensions by use of multiply scattered light

Rajesh Shinde, Ganesh Balgi, Steven Richter, Sukanta Banerjee, Jeffery Reynolds, Joseph Pierce, and Eva Sevick-Muraca
Appl. Opt. 38(1) 197-204 (1999)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (3)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (4)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.