Polarization aberration analysis of the advanced x-ray astrophysics facility telescope assembly

Not Accessible

Your library or personal account may give you access

Abstract

The advanced x-ray astrophysics facility (AXAF) telescope consists of six concentric paraboloid–hyperboloid pairs of mirrors that operate near grazing incidence. Because of the substantial polarization effects at large angles of incidence there has been concern regarding the feasibility of doing polarimetry near the telescope focal plane. The primary mirror is shown to act as a tangentially directed half-wave linear retarder and to almost completely depolarize the linearly polarized component of the light. The secondary mirror introduces an additional half-wave of linear retardance. The two-mirror telescope assembly acts as a tangentially directed one-wave linear retarder. Each mirror depolarizes alone but together the two-mirror assembly preserves the polarization state. The net instrumental polarization effects are small and polarimetry is feasible with AXAF.

The polarization aberration function for the telescope is derived by using Jones calculus. Polarization aberration functions are used to calculate the effect of instrumental polarization on the transmitted wave front and the polarization state that is due to the primary mirror and the telescope assembly.

© 1992 Optical Society of America

Full Article  |  PDF Article

Corrections

Russell A. Chipman, Daniel M. Brown, and James P. McGuire, "Polarization aberration analysis of the advanced x-ray astrophysics facility telescope assembly: errata," Appl. Opt. 32, 4236-4237 (1993)
https://opg.optica.org/ao/abstract.cfm?uri=ao-32-22-4236

More Like This
Polarization aberration analysis of the advanced x-ray astrophysics facility telescope assembly: errata

Russell A. Chipman, Daniel M. Brown, and James P. McGuire
Appl. Opt. 32(22) 4236-4237 (1993)

Polarizing properties of grazing-incidence x-ray mirrors: comment

J. Sánchez Almeida and V. Martínez Pillet
Appl. Opt. 32(22) 4231-4235 (1993)

Aberrations for grazing incidence telescopes

Timo T. Saha
Appl. Opt. 27(8) 1492-1498 (1988)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (18)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (37)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved